Installing The Power Distribution Board (T-Docking) - HP Integrity rx4610 User Manual

Hp server rx4610 user guide
Hide thumbs Also See for Integrity rx4610:
Table of Contents

Advertisement

Chapter 8
Figure 8-10. Removing the Power Distribution Board (T-Docking)

Installing the Power Distribution Board (T-Docking)

To install the Power Distribution Board (T-Docking), complete the following
procedure:
1. Remove the U-shaped handle on the original Power Distribution Board (T-
Docking) and attach it to the replacement board.
2. Place the Power Distribution Board (T-Docking) into position, taking care
to locate the board over the indexing stake in the middle and not over the
SCSI cable.
3. Engage the connector on the side of the Power Distribution Board (T-
Docking) to the Sideplane. Be sure that the connector on the Power
Distribution Board (T-Docking) is aligned correctly with the Sideplane
before pressing the board down.