Hot Swapping The 120 Mm Fans; Removing The 120 Mm Fans - HP Integrity rx4610 User Manual

Hp server rx4610 user guide
Hide thumbs Also See for Integrity rx4610:
Table of Contents

Advertisement

Chapter 3

Hot Swapping the 120 mm Fans

The two 120 mm cooling fans are mounted on the top front of the chassis. These
fans can be replaced without shutting down power to the system. If it is a failed
fan, the amber LED will be illuminated on the front panel, and the amber LED on
the failed fan itself will be illuminated. The individual fan LEDs may be seen
through view-ports in the fan covers

Removing the 120 mm Fans

To remove the 120mm fan, complete the following procedure:
1. Slide the server out of the rack far enough to expose the fan-access door on
the top of the chassis.
2. Unscrew the thumbscrew on the front of the fan-access door and lift the
door open. If a fan has failed, the amber LED light is illuminated.
CAUTION
Do not leave the door open for an extended time. Cooling of
the system could be reduced
3. Grasp the fan assembly through the finger holes and pull the assembly out.
22
Installing Fans and Power Supplies

Advertisement

Table of Contents
loading

Table of Contents