Appendix A
Including the BMC in the JTAG Chain
Jumper block J8D1 lets you include or exclude the BMC in the JTAG chain. By
default, the BMC is excluded from the JTAG chain.
Jumper setting diagram labeled:
A. Excludes BMC from the JTAG Chain (Default Setting)
B. Includes BMC in the JTAG Chain
Overriding the hardware PCI Hot Plug Interlock
Jumper block J1A1 lets you override the hardware PCI hot plug interlock
switches. By default, the jumper setting allows for the slot's interlock switch
and/or the PID's GPIO27 to set the interlock value.
Figure A-23. Hardware PCI Hot Plug Interlock Override Jumper Settings
Jumper settings diagram labeled:
A. Allows the PCI Hot Plug Interlock Switch and/or the PID's GPIO27 to
Set the Interlock Value (Default Setting)
B. Overrides the Hardware PCI Hot Plug Interlock Switch
226
J8D1
J8D1
1
1
A
B
Figure A-22. BMC Jumper Settings
J1A1
J1A1
1
1
A
B