Hot-Plug Fans - HP ProLiant DL360 Gen10 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL360 Gen10:
Table of Contents

Advertisement

Item
Description
4
Drive status LED
5
Adapter ejection release latch
and handle

Hot-plug fans

CAUTION:
To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a single-
processor configuration.
CAUTION:
To avoid damage to the equipment, do not operate the server for extended periods of time if the server
does not have the optimal number of fans installed. Although the server might boot, Hewlett Packard
Enterprise does not recommend operating the server without the required fans installed and operating.
The valid fan configurations are listed in the following tables.
One-processor configuration
Fan bay 1
Fan blank
Two-processor configuration
Fan bay 1
Fan
Fan bay 2
Fan bay 3
Fan blank
Fan
Fan bay 2
Fan bay 3
Fan
Fan
Status
Off—The drive is not configured by a RAID
controller
Solid green—The drive is a member of one or more
logical drives
Flashing green (4 Hz)—The drive is operating
normally and has activity
Flashing green (1 Hz)—The drive is rebuilding or
performing a RAID migration, stripe size migration,
capacity expansion, logical drive extension, or is
erasing
Flashing amber/green (1 Hz)—The drive is a
member of one or more logical drives that predicts
the drive will fail
Solid amber—The drive has failed
Flashing amber (1 Hz)—The drive is not configured
and predicts the drive will fail
Removes the SFF flash adapter when released
Fan bay 4
Fan bay 5
Fan
Fan
Fan bay 4
Fan bay 5
Fan
Fan
Fan bay 6
Fan bay 7
Fan
Fan
Fan bay 6
Fan bay 7
Fan
Fan
Hot-plug fans
95

Advertisement

Table of Contents
loading

Table of Contents