Upgrade Disk Drive Firmware On Stand-Alone K2 System - GRASS VALLEY K2 7.3.8 - RELEASE NOTES AND Quick Start Manual

Release notes & upgrade instructions
Table of Contents

Advertisement

Upgrading K2 systems
13. Put AppCenter channels back online.
14. Restart.

Upgrade disk drive firmware on stand-alone K2 system

Do not do this task if:
A K2 system with disk drive rmware already at a compatible version, as listed in compatibility
speci cations.
Do this task if:
A K2 system with disk drive rmware that you need to upgrade, as listed in compatibility
speci cations.
For internal storage K2 Summit/Solo systems, nd compatibility speci cations at
Summit/Solo components
storage, nd compatibility speci cations at
NOTE: The disk drives are upgraded one at a time which can take as long as 2 minutes per drive.
Take this into consideration when scheduling the upgrade.
1. Open AppCenter Workstation, either on the local K2 system or on the control point PC and
logon.
Make sure you logon to AppCenter with appropriate privileges, as this logon is passed to Storage
Utility. Administrator-level permission is necessary for most Storage Utility operations. If you
log in with user-level permissions, the Storage Utility menu item is disabled.
2. If you are running AppCenter from a control point PC and you have channels from multiple K2
systems in your channel suite, select a channel from the stand-alone K2 system whose storage
you intend to con gure with Storage Utility. This is important as Storage Utility automatically
connects to the K2 system that hosts the currently selected channel.
NOTE: Make sure you are connecting to a stand-alone K2 system. You should never connect
Storage Utility directly to a K2 system that uses shared (SAN) storage.
3. From the AppCenter
Storage Utility opens.
4. If you are connecting from a control point PC, you should verify that you are connected to the
correct K2 system. To verify this, use the Identify feature to ash the disks on the K2 system.
5. Select a disk drive icon in the Storage Utility tree view, then note the rmware version in drive
properties reported in the right-hand pane. Proceed if you need to download disk drive rmware.
6. Right-click a disk in the tree view, then select
menu.
7. If online, messages appear
system in of ine mode.
AppCenter channels go of ine. The Open File dialog box opens.
8. In the Open File dialog box browse to the directory and le as listed in compatibility tables
earlier in these release notes. You must select the correct le for the device, storage type, and
drive size/type.
76
K2 Version 7.3.8 Release Notes & Upgrade Instructions
on page 31. For a K2 Summit Production Client with direct-connect
Compatible K2 RAID components
menu, select
System
Storage Utility
of ine mode now? and
.
Advanced | Download Disk Firmware
continue? . Click
Compatible K2
on page 35.
in the context
to put the K2
Yes
23 November 2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents