Upgrading K2 systems
For internal storage K2 Summit/Solo systems, nd compatibility speci cations at
Summit/Solo components
storage, nd compatibility speci cations at
NOTE: The disk drives are upgraded one at a time which can take as long as 2 minutes per drive.
Take this into consideration when scheduling the upgrade.
1. Open AppCenter Workstation, either on the local K2 system or on the control point PC and
logon.
Make sure you logon to AppCenter with appropriate privileges, as this logon is passed to Storage
Utility. Administrator-level permission is necessary for most Storage Utility operations. If you
log in with user-level permissions, the Storage Utility menu item is disabled.
2. If you are running AppCenter from a control point PC and you have channels from multiple K2
systems in your channel suite, select a channel from the stand-alone K2 system whose storage
you intend to con gure with Storage Utility. This is important as Storage Utility automatically
connects to the K2 system that hosts the currently selected channel.
NOTE: Make sure you are connecting to a stand-alone K2 system. You should never connect
Storage Utility directly to a K2 system that uses shared (SAN) storage.
3. From the AppCenter
Storage Utility opens.
4. If you are connecting from a control point PC, you should verify that you are connected to the
correct K2 system. To verify this, use the Identify feature to ash the disks on the K2 system.
5. Select a disk drive icon in the Storage Utility tree view, then note the rmware version in drive
properties reported in the right-hand pane. Proceed if you need to download disk drive rmware.
6. Right-click a disk in the tree view, then select
menu.
7. If online, messages appear
system in of ine mode.
AppCenter channels go of ine. The Open File dialog box opens.
8. In the Open File dialog box browse to the directory and le as listed in compatibility tables
earlier in these release notes. You must select the correct le for the device, storage type, and
drive size/type.
9. Click
For internal drives, watch the lights on the drive to which you are downloading rmware. The
lights ash as rmware loads. Wait until the lights have completed their ashing pattern. This
can take several minutes.
The Progress Report window appears showing the disk rmware download task and the percentage
completion.
10. Repeat this procedure on each drive.
11. When nished, exit Storage Utility.
12. Put AppCenter channels back online.
13. Restart.
94
K2 Version 7.3.8 Release Notes & Upgrade Instructions
on page 31. For a K2 Summit Production Client with direct-connect
menu, select
System
.
OK
Compatible K2 RAID components
Storage Utility
Advanced | Download Disk Firmware
of ine mode now? and
Compatible K2
on page 35.
.
continue? . Click
Yes