Setting The Zone Bypass Scheme - Visonic POWERMASTER-10 User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10:
Table of Contents

Advertisement

MENUS AND FUNCTIONS
C.1 Setting the Zone Bypass Scheme
Bypassing permits arming only part of the system while allowing free movement of people within certain zones
when the system is armed.
It is also used to temporarily remove from service faulty zones that require repair work or to deactivate a sensor
if, for example, you are decorating a room.
♦ Here you can set the Zone Bypass Scheme i.e. to scroll through the list of registered (enrolled) sensors to
your PowerMaster-10 system and to Bypass (deactivate) faulty or disturbed sensors (either READY or
NOT-READY) or to Clear (reactivate) BYPASSED zones (sensors).
Once you have set a Bypass Scheme you can use the following 3 options:
>
To quickly review the bypassed zones – refer to section C.2.
>
To quickly clear a bypassed zone i.e. to reactivate the bypassed zone – refer to section C.2.
>
To repeat (recall) the last used zone bypassing scheme – refer to section C.3.
1. Zones will be bypassed throughout one disarm-arm period only. Disarming the system after arming will
suspend the entire bypassing scheme but you can recall and reuse it as described in section C.3.
2. Fire zones cannot be bypassed.
3. Carefully read the section titled "Additional Information" according to the indicated references
table at end of section C.3.
A. To Bypass a Zone
1.
SET ZONE BYPASS
Z01: READY
Living Room
2.
or
Z04: NOT READY
3.
Kitchen
4.
<OK> TO BYPASS
5.
Z04: BYPASSED
16
REMEMBER – ZONE BYPASSING COMPROMISES SECURITY!
Enter the USER SETTINGS menu and select the [SET ZONE BYPASS] option
and press the
The first zone, Z01, is displayed.
Click the
to bypass (or clear bypass), for example, "Z04" for Zone 04. After several
seconds the LED on the respective device starts flashing indicating "it's me".
When the display reads the zone you wish to bypass press
confirm.
The display now reads [<OK> TO BYPASS]
To bypass the selected zone press
A "Happy Tune"
[Z04: BYPASSED].
button to confirm.
1
2
or
button until the display reads the zone you wish
. 3
sounds and the updated zone status is now displayed i.e.
5
etc – see
1
to
D-302757

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents