Visonic POWERMASTER-10 User Manual page 38

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10:
Table of Contents

Advertisement

C. To Test all other Devices
TEST ALL DEVICES
7.
8.
NOT ACTIVE NNN
Z01 NOT ACTIVE
Z01 CONTACT
FRONT DOOR
9.
10.
DEVICE TESTS END
READY 00:00
1
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
2
If you have not already changed your personal code number, use the default setting – 1111.
3
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will
also provide the link quality indication – see PowerMaster-10 Installer Manual.
4
To skip the SIRENS TEST and select the other devices TEST, press
5
The Periodic test can be performed on a maximum of three sirens including one internal siren. Outdoor
sirens are activated with low volume.
6
How to activate system devices during the "Periodic Test". Make sure the LED on the device lights when
activated, as follows:
Contact sensor: Open or close the door or window protected by the contact.
Motion sensors: Perform a "walk test" of the detector as explained in the detector's datasheet.
Smoke sensors: Perform a "Diagnostic test" as explained in the detector's datasheet.
Keyfob:
Keypads:
Repeater:
Other devices:
7
a. Three seconds after the device is displayed, the device LED blinks continuously to assist you to identify
("it's me").
b. To end the session, press the
.
D-302757
The display now reads [TEST ALL DEVICES].
To enter the devices test procedure press
The display now reads [NOT TESTED NNN]. NNN indicates the number of
enrolled devices in the control panel that have not been tested yet. This
number automatically drops one count for every tested device.
To initiate the devices test press
The display shows the 1
between the device number, the device type (e.g. magnetic contact ,keyfob,
keypad, etc.), and the device location.
The test is performed by activating each device as explained in the table
6
below.
Click
When all devices have been activated, the display reads [DEVICE TESTS
END] followed by [READY 00:00].
Additional Information (Periodic Test)
Activate any of the keyfob buttons.
Perform a disarm or arm routine or press any other key that activates the LED.
Follow the "Diagnostic Tests" described in the repeater's datasheet.
In general, follow the "Diagnostic Tests" described in the device's datasheet or activate
any of its functions.
TESTING THE SYSTEM
st
device in the list of untested devices. It alternates
to scroll through the list of all untested devices.
button until the display reads [
.
.
7
.
<OK> TO EXIT
] then press
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents