IMPORTANT! If the trouble beeps bother you, disarm
the system again (even though it is already disarmed).
This will cancel the trouble beeps for 4 hours.
C. Reviewing Memory & Troubles at the Same Time
If alarms / tamper events are retained in the alarm
memory and at the same time a state of trouble
exists, the display will first read the alarm memory
followed by trouble events, as described in sections
A & B above.
Fault
1-WAY
AC FAILURE
AC SUPPLY FAILURE
CLEAN ME
COMM. FAILURE
CPU LOW BATTERY
CPU TAMPER
FUSE TROUBLE
GAS TROUBLE
GSM NET FAIL
JAMMING
LOW BATTERY
MISSING
NOT NETWORKED
RSSI LOW
SIREN AC FAILURE
LINE FAILURE
D-302757
REVIEWING TROUBLES AND ALARM MEMORY
What it means
The device functions but can not "hear" the panel. The control panel cannot
configure or control the device. Battery consumption increases.
There is no power to gas sensor
There is no power and the system is working on backup battery power
The fire detector must be cleaned
A message could not be sent to the monitoring station or to a private telephone (or a
message was sent but was not acknowledged)
The backup battery within the control panel is weak and must be replaced (see
Chapter 7 - Replacing Backup Battery).
The control panel was physically tampered with or its cover was opened, or it was
removed from wall.
The PGM fuse is burnt out or overloaded.
Gas detector failure
The GSM communicator is not able to connect to the cellular network.
A radio-frequency signal which is blocking all communication frequency channels
between the sensors and control panel is detected.
The battery of the indicated device is near the end of its useful life.
A device or detector has not reported for some time to the control panel.
A device was not installed or not installed correctly, or, cannot establish
communication with the control panel after installation.
The GSM communicator has detected that GSM network signal is weak
There is no power to the siren
There is a problem with the telephone line

Correcting Trouble Situations

The
trouble
indications
indicator and flashing TRBL message) are cleared
once you eliminate the cause of trouble. The table
below describes the system faults and respective
corrective actions. If you do not know how to cope
with a trouble situation, report it to your installer
and seek his advice.