Reviewing Troubles And Alarm Memory; Alarm & Tamper Memory; Troubles - Visonic POWERMASTER-10 User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10:
Table of Contents

Advertisement

REVIEWING TROUBLES AND ALARM MEMORY

3. Reviewing Troubles and Alarm memory
Alarm & Tamper Memory
The PowerMaster-10 retains in it's memory alarm and
"tamper" events that occurred during the last arming
period.
Note: Alarm events are memorized only after expiry of
the "abort period" (see Appendix A). This means that if
you disarm the system immediately - before the abort
period expires - there will be no memory indication
A. Indication of Alarm & Tamper Condition
If the system is disarmed following an alarm event, a
flashing MEMORY message will be displayed, as
follows:
READY
(alternating)
READY
or, if the system is not ready for arming -
NOT READY
(alternating)
NOT READY
B. Displaying Alarm & Tamper Information
To review memory content, click
EXAMPLE: An alarm was triggered because the garage
door - zone No. 12 – was opened but then closed. In
addition, the bedroom motion detector - zone No. 7 -
sent a "Tamper" message because its cover had been
removed.
PRESS
In response to additional clicking of the
button, the display shows details of other events
retained in open tamper (if any), or reverts to its
initial state (see A above).
If the system is NOT READY, the display will first read
the open zones and then alarm memory events.
Remember! The memory indication and content will
be cleared upon the next arming of the system.
10
HH:MM
MEMORY
HH:MM
MEMORY
button.
RESULTANT DISPLAY
READY
HH:MM
Z12 ALARMED
(alternating)
GARAGE DOOR
Z07 TAMPER-OPEN
(alternating)
BEDROOM
READY
HH:MM

Troubles

A. Indication of Trouble condition
If the system detected a trouble condition in any of the
enrolled devices, the TROUBLE indicator illuminates,
3 beeps are sounded once per minute and a flashing
TRBL message is displayed, as follows.
READY
(alternating)
READY
or, if the system is not ready for arming -
NOT READY
(alternating)
NOT READY
B. Displaying Trouble Information
All trouble messages need to be reviewed and
corrected as described below:
EXAMPLE: The kitchen device - zone No. 9 - has
reported a low battery – the living room device zone
No. 15 - has been inactive, and an attempt to
communicate a message to your telephone has
failed. However, these troubles do not prevent the
system from being "ready to arm".
To review the source of the current troubles one by
one, click the
below:
PRESS
HH:MM
TRBL
HH:MM
TRBL
button repeatedly as shown
RESULTANT DISPLAY
READY
HH:MM
Z09 LOW BATTERY
(alternating)
Z09 CONTACT
(alternating)
KITCHEN
Z15 MISSING
(alternating)
Z15 MOTION SENS.
(alternating)
LIVING ROOM
COMM. FAILURE
READY HH:MM
D-302757

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents