TESTING THE SYSTEM

7. Testing the System

Periodic Test

The components of your security system are designed to be maintenance-free as much as possible.
Nevertheless, it is mandatory to test the system at least once a week and after an alarm event to verify that all
system sirens, detectors keyfobs, keypads and other peripherals function properly. Proceed as described in this
section and if there is any problem, notify your installer at once.
The test is performed in two parts:
Siren Test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume).
Device Test: Each device in the system is activated by the user and the display indicates to the user which
devices were not yet tested and the "it's me" indication helps to identify them if necessary. A counter also
indicates the number of the devices that remain untested.
Carefully read the section titled "Additional Information" according to the indicated references
at end of this section.
A. To Enter the Periodic Test Menu
1.
READY 00:00
PERIODIC TEST
2.
ENTER CODE:
CODE
3.
Go to step 4
B. To Test the Sirens
4.
SIRENS TEST
5.
SIREN N
6.
SIRENS TESTS END
or
36
Make sure the system is disarmed and then press the
repeatedly until the display reads "PERIODIC TEST" and press
1
confirm.
The screen will now prompt you to enter your user code.
Enter your User Code.
The display now reads [SIRENS TEST].
To initiate the siren test press
all 4 LED's on the panel should light (LED test).
The display now reads [SIREN N]. This indicates the number of enrolled
sirens in the control panel that have not been tested.
First the panel siren sounds for 3 seconds after which the PowerMaster-10
system will automatically repeat the procedure for the next siren enrolled in
the system until all sirens are tested.
You should listen to the sirens sounds and make sure that all sirens sound.
When all the sirens have been tested, the display reads [SIREN TESTS END].
Press the press
move to the next step to test the other devices.
2 3
4
. Immediately after pressing
5
or the
button to confirm the test and then
1
etc – see table
2
4
D-302757
button
to
,

Hide quick links: