Installing the Rack Server
To install the cage nuts:
1. Position one of the cage nuts on the inside of a vertical rail on the front of the
rack.
2. Compress the sides of the cage nut and insert both lips into the square cutout on
the rail.
NOTE: Use a fitting tool as an aid to help install the cage nuts, if needed.
Figure 4-3: Inserting cage nuts
3. Repeat steps 1 and 2 for a second cage nut.

Installing Server Rails

To install the server rails on the server:
IMPORTANT: Install the server rails with the smooth side of the rail against the server
chassis.
1. Align the four keyholes on one of the server rails with the four spools on the side
of the chassis. The closed, tapered end of the rail points toward the rear panel of
the server.
4-6