HP 195294-001 - ProLiant - ML370R Setup And Installation Manual page 107

Hp proliant ml370 generation 3 setup and installation guide
Hide thumbs Also See for 195294-001 - ProLiant - ML370R:
Table of Contents

Advertisement

Installing Hardware Options
Installing the Redundant Hot-Plug Fan Cage
The redundant hot-plug fan cage is installed inside the chassis, directly above the
primary power supply. For full redundancy, always install all three fans included in
the redundant hot-plug fan cage option kit.
To install the redundant hot-plug fan cage:
1. Power down the server. Refer to "Powering Down the Server" in this chapter.
2. Remove the access panel. Refer to "Removing the Access Panel" in this chapter.
3. Loosen the two thumbscrews on the redundant fan cage retaining bracket (1).
4. Remove the bracket from the chassis (2).
IMPORTANT: Do not discard the fan cage retaining bracket. The bracket is required for
proper fan operation.
Figure 3-51: Removing the redundant fan cage retaining
bracket
3-62
HP ProLiant ML370 Generation 3 Server Setup and Installation Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml370 - proliant - g3Ml370 - proliant - g3

Table of Contents