Printing Quality

Symptom
Cause
Vertical
The imaging unit,
white lines
transfer roller, or fuser
appear in
unit are is
image.
misinstalled, old, or
damaged.
Image is
The media is moist
too light;
from humidity.
there is low
One or more toner
image
cartridges are
density.
defective.
The imaging unit is old
or damaged.
Media type may be set
incorrectly.
The printer is
connected to an outlet
with a voltage or
frequency that does
not match the printer
specifications.
Driver settings are
not correct.
Media is the wrong
size.
Unsupported media is
being used.
88
Solution
Confirm the proper installation of the items,
and check them for damage. If necessary,
replace them.
Remove the moist media and replace with
new, dry media.
Remove the toner cartridges and check for
damage. If necessary, replace them.
Remove the imaging unit and check for
damage. If necessary, replace it.
Envelopes, glossy stock (set as Thick 2 or
Thick 3), labels, and thick stock have to be
set in the correct mode. See "Media" on
page 32.
Use a power source with the proper
specifications.
Confirm that you are using the correct
driver settings.
Check with your documentation to confirm
the correct media size and type.
Check www.minolta-qms.com/support
(click on Answer Base) for currently
approved media. To order approved media,
go to www.q-shop.com.
Solving Problems