In compliance with UL guidelines, "The appliance inlet is considered to
be the main disconnect device."
Power
Voltage
Fluctuation
Rate and Rated
Line Voltage
Frequency
Variation Rate
Fused
Printer
Maximum
Electrical
Current
Noise-
generating
Equipment
Grounding

ENERGY STAR Compliance

The magicolor 3100 basic configuration is
compliant with US Environmental
Protection Agency (EPA) ENERGY STAR
regulations. After a user-configurable
period of inactivity, the printer changes to
a low-power state (the engine remains on,
but the fuser turns off). When a print job is
received, the printer returns to
normal power.
Requirements
Japan
100 VAC 50/60 Hz 8 amps
North America 120 VAC 50 Hz 8 amps
Europe
220–240 VAC 50/60 Hz 4 amps
Latin America
115/120 VAC 50/60 Hz 8 amps
220–240 VAC 50/60 Hz 4 amps
Notes: Amperage capacity at least 1.2 times that used by
the printer.
Japan
100 VAC ±10%
North America 120 VAC ±10%
Europe
220–240 VAC ±10%
Latin America
120 VAC ±10%
220–240 VAC ±10%
Notes: 10% of the rated line voltage for proper operation.
Within 50–60 ±3 Hz
For at least 15 amperes (8 amperes for 240 V).
Draws 8 A at 100 V, 110 V, or 120 V; or 4 A at 220 V or
240 V.
Required during operation is 8 amps for a 100 V or a 120 V
system and 4 amps for a 220–240 V system.
Should not be connected to the same electrical outlet as
the printer.
Your printer requires a properly grounded AC outlet.