[12] FNS Adjusting the Magnets on
Conveyance Guide Plate B
1. Tool used
• Phillips-head screwdriver
2. Preparation
(1) Open the front cover.
(2) Check whether conveyance guide plate B makes
contact with the cushioning rubber when the
magnets are stuck to conveyance guide plate A.
(3) If plate B does not make contact with the cushion-
ing rubber, remove the rear cover and carry out
adjustment as described below.
3. Adjustment Procedure
(1) Detach all FNS CB (FNS control board) connec-
tors.
(2) Remove the 2 set screws holding the FNS CB in
place. Remove the FNS CB together with its
bracket.
Bracket
Screws
(3) Loosen the 4 magnet-holding set screws (two at
the front and two at the back), and move convey-
ance guide plate B all the way in the direction
indicated by the arrow.
FNS CB (Finisher Control Board)
(4) Remove the E-ring and the gear.
(5) Adhere the magnets to conveyance guide plate A
and retighten the set screws.
(6) Reassemble in opposite sequence to removal.
1 - 119
OTHER ADJUSTMENT
Magnet
(rear)
Magnet
(front)
Gear
E-ring
Conveyance
Conveyance
Guide Plate A
Guide Plate B