[13] Recall Standard Data
(Image Adjustment)
Restoring image adjustment settings to standard val-
ues (data after process adjustment).
Step
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press
Image adjustment.
2
3
[Image Adjustment Menu Screen]
Select
Recall standard data.
7
4
[Recall Standard Data Screen]
Press the
YES
Various data are restored to standard
values.
5
Press the
PREVIOUS SCREEN
turn to the Image Adjustment Menu
Screen.
Operation
key.
key to re-
1 - 71

[14] Running Test Mode

Testing continuous copy operation.
Select
Running Test Mode in the 36 Mode Menu
3
Screen.
This adjustment consists of the following items:
1.
Intermittent copy mode
In this mode, the machine goes into the copy
ready state after completing a set number of copy
operation, waits 0.5 sec, and then repeats the
same operation.
2.
Paperless intermittent copy mode
In this mode, the machine makes copies at approxi-
mately the same timing as for normal copy without
performing paper detection or jam detection. In
addition, similar to intermittent copy mode, the ma-
chine goes into the copy ready state after complet-
ing a set number of copy operation, waits 0.5 sec,
and then repeats the same operation.
3.
Paperless mode
In this mode, the machine makes copies at approxi-
mately the same timing as for normal copy without
performing paper detection or jam detection.
4.
Paperless endless mode
In this mode, the copy quantity is set to infinity.
In addition, similar to Paperless mode, the ma-
chine makes copies at approximately the same
timing as for normal copy without performing
paper detection or jam detection.
5.
Running mode
This mode consists of Paperless endless mode
with repetitive optical scan and auto paper feed
tray change.
Step
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press
Running test mode.
3
3
[Running Test Mode Menu Screen]
Press mode keys
4
[Copy Screen]
Press the Start button.
5
Check the copy operation and then press
the Stop/Clear button to stop.
6
Turn off the main switch and exit Run-
ning Test Mode.