Fns Adjusting The Paper Exit-Opening Lower Guide Plate - Minolta DI750 - MANUAL SERVICE Service Manual

Table of Contents

Advertisement

OTHER ADJUSTMENT
[20] FNS Adjusting the Paper Exit-
Opening Lower Guide Plate
1. Tools used
• Screwdriver (Phillips)
• Scale
2. Preparation
(1) Remove the following parts.
• Rear cover
• Top cover
• Cover Inserter A (if installed)
(2) With SD4 (paper exit-opening solenoid) OFF,
confirm that the paper exit-opening lower guide
plate is a sufficient distance (distance A) higher
than the sponge rollers.
Spec value: A = 1.5mm and greater
A=1.5mm and greater
Sponge Roller
Lower Guide Plate
(3) Hold down the paper exit-opening lower guide plate
with your hand so that the paper exit roller makes
contact, and check that the remaining stroke for
solenoid SD4 (distance B) is within spec.
Spec value: B = 2.5±0.5mm
SD4 (Paper Exit
Opening)
(4) If either measurement is out of spec, carry out
adjustment as described below.
3. Adjustment Procedure
(1) Loosen the 2 set screws holding the solenoid
bracket in place, and adjust the position of the
bracket so that distances A and B are within spec.
(2) Retighten the 2 bracket set screws.
(3) Reassemble in the reverse sequence to removal.
1 - 128
B=2.5–0.5mm
Paper Exit
Lower
Guide Plate
Solenoid Bracket
Screws