[7] Relationships between processing states and operational LEDs

Note : This is only when installing the program to graphics control for the first time.
Timer
Power save
ON/OFF
No.
1
Initializing CPU now
2
Checking memory
3
Memory check error (waiting for data from PC)
4
ISW processing (receiving data)
5
ISW processing (writing to flash memory)
6
Transfer data error
7
Flash write error
8
Memory check successful and reboot

[8] Rewriting procedure after an error interruption

If errors occur while writing ROM data, it is written the same way as explained in "Writing ROM data newly"
in [3]-2, "Instances of ISW transfer."
- Graphics control program
The timer LED (orange) flashes. (Nothing will appear on the operation LCD because communication with the
operating unit is disabled.)
Retry ISW after turning the main switch OFF, then ON.
- Operation control program
Since the 25 mode is disabled, launch the HELP + CHECK mode to run ISW.
- Other control programs
Relaunch the 25 mode to retry ISW. (It is assumed that the copier has both the graphics control and
operation control programs successfully installed.)
Timer
OFF
OFF
Flashing
OFF
OFF
Flashing
Flashing
OFF
2 - 11
ISW
Power Save
OFF
OFF
OFF
Flashing
Flashing
Flashing
Steady lit
OFF