3
SCOPE OPERATION (ADVANCED)
Spectrum scope screen
D Using the Scroll mode
Displays signals within a selected span. When the
operating frequency moves outside of the screen, the
displayed frequency range automatically scrolls.
1. Display the SPECTRUM SCOPE screen.
» SCOPE
MENU
2. Touch [CENT/FIX] for 1 second to select the
Scroll mode.
• When changing the Center mode to the Scroll mode,
"SCROLL-C" is displayed. You can change the scope
span by touching [SPAN].
• When changing the Fixed mode to the Scroll mode,
"SCROLL-F" is displayed. You can change the Edge
frequencies by touching [EDGE].
3. Touch [CENT/FIX] to return to the previous mode.
• When returning to the Center mode, the scope span
does not return to the previous setting.
• When returning to the Fixed mode, the Edge
frequencies return to the last selected "Fixed Edges."
If the operating frequency is below the lower Edge
frequency, or above the upper Edge frequency, "<<"
or ">>" is displayed in the upper side corners of the
SPECTRUM SCOPE screen.
SCROLL-F mode*
* When in the SCROLL-C mode,
3-3
is displayed.