10 | Operation
Pellet operation
In pellet operation, pellet quantity and combustion air are
supplied according to the set heat output.
The desired room temperature must be set in the room
temperature display. If this is reached, the stove automatic-
ally regulates to the lowest output level or switches OFF if
Fig. 47: Pellet operation
the ECO function is enabled (see Settings/ECO mode).
Pressing the stop button switches the stove into burnout
phase.
The current room temperature is measured using a cable-
attached temperature sensor on the back of the appliance.
In pellet operation, a fluctuating chimney draught or in-
creasing contamination of the exhaust gas pipes is automat-
ically balanced by the exhaust gas fan.
For combination appliances (dual appliances) only: If during
the pellet operation the door is opened and closed again,
the stove switches into hybrid start.