Fuel
Log, moisture content ≤
25 %
Compregnated laminated
wood,
moisture content < 12 %
Other woody biomass
Non-woody biomass
Anthracite and dry steam
coal
Coking coal
Semi-coke
Bituminous coal
Lignite briquettes
Peat briquettes
Briquettes made from a
mixture of fossil fuels
Other fossil fuels
Briquettes made from a
mixture of biomass and
fossil fuels
Other mixture of biomass
and solid fuels
(*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide
(**) Only required when using correction factors F(2) or F(3).
EN
Preferred
Other suit-
fuel
able fuel(s)
2
(only one)
:
no
no
yes
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
Space heating emis-
ηs
3
:
[x%]:
sions at nominal heating
efficiency (*)
PM OGC CO
[x] mg/Nm³ (13% O2)
-
-
-
87.6
19
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5 | Technical data
Space heating emis-
sions at minimum
heat output
NOx
PM OGC CO NOx
5
[x] mg/Nm³ (13%
6
O2)
-
-
-
-
11
123
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
(*) (**)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15