Austroflamm Ruby 2.0 Operating Manual page 100

Table of Contents

Advertisement

16 | Help
Warning
Description
code
Error code
Error - E105 Software error
Error - E107 Firebox temperature sensor
defective
Error - E108 Safety temperature limiter
triggered or defective
Error - E109 Pellet hopper lid open rid-
dling grate not closed
Error - E110 Room temperature sensor
defective
Error - E113 Firebox temperature too
high
Error - E114 Ignition phase 2 failed fire-
box temperature too low
(pellet operation)
Error - E115 Software error or controls
defective
100
EN
Possible cause
Firebox temperature sensor faulty
or incorrectly connected.
Room temperature sensor faulty
or incorrectly connected.
Exhaust gas fan and flues are
blocked.
1. The pellet hopper is empty.
2. Lower-quality or old pellets.
3. The screw conveyor is blocked.
4. Firebox temperature sensor
faulty or incorrectly connected.
5. Other errors
Operating manual Ruby 2.0
Solution
Empty the combustion pot, reset
the error and restart the stove.
Should the error persist, please
contact your Austroflamm dealer
Please contact your Austroflamm
dealer. The software must be rein-
stalled.
Should the error persist, please
contact your Austroflamm dealer.
The firebox temperature sensor
must be replaced or correctly con-
nected.
Please contact your Austroflamm
dealer to find out why the STL has
been activated.
Close pellet hopper lid.
Check and clean the riddling
grate.
Should the error persist, please
contact your Austroflamm dealer.
Should the error persist, please
contact your Austroflamm dealer.
The room temperature sensor
must be replaced or correctly con-
nected.
ATTENTION: Only carry out when
stove is cold!
ATTENTION: Only carry out when
stove is cold!
1. Check whether there are pellets
in the pellet hopper and in the
screw conveyor, and top up pel-
lets if necessary.
2. Replace the pellets.
3. Please contact your Austro-
flamm dealer. The screw conveyor
needs cleaning.
4. Please contact your Austro-
flamm dealer. The firebox temper-
ature sensor must be replaced or
correctly connected.
Empty the combustion pot, reset
the error and restart the stove.
Should the error persist, please
contact your Austroflamm dealer.
Please contact your Austroflamm
dealer. The software must be rein-
stalled or the controls must be re-
placed.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ruby 2.0 and is the answer not in the manual?

Questions and answers

Table of Contents