  • Page 1 Operating manual Ivy 2.0 945027 www.austroflamm.com...
  • Page 2 Tel: +43 (0) 7249 / 46 443 www.austroflamm.com info@austroflamm.com Edited by: Olivera Stojanovic Illustrations: Konstruktion Text: Technical department (Austroflamm) Copyright All Rights reserved. The contents of these instructions may be reproduced or distributed only with the consent of the publisher! Printing, spelling and typographical errors reserved.
  • Page 3: Table Of Contents

    Operating manual Ivy 2.0 945027 Contents Contents General information ............................Copyright.............................. Purpose of the manual ............................Storing the manual ..........................Structure of the manual........................Representations used.......................... Version control............................. Abbreviations ............................Safety ..................................Importance of the safety instructions ....................Warning of sources of danger ......................
  • Page 4 Contents Operating manual Ivy 2.0 945027 9.2.2 Installing the HMS..........................24 9.2.3 Mounting the Keramott........................25 9.2.4 Mounting the base ..........................25 9.2.5 Mounting the side box ........................26 9.2.6 Installing the log drawer ........................27 9.2.7 Mounting the external air connection at the rear ................28 10 Settings.................................
  • Page 5: General Information

    Operating manual Ivy 2.0 945027 1 | General information General information You have decided in favor of an Austroflamm stove. Congratulations on your decision and thank you for your trust. Correct operation and care are essential for trouble-free operation and long service life.
  • Page 6: Purpose Of The Manual

    2 | Purpose of the manual Operating manual Ivy 2.0 945027 Purpose of the manual This manual is a component part of the stove and is intended to contribute to the stove being safely in- stalled and maintained. Please read this manual before using the stove for the first time.
  • Page 7: Abbreviations

    Operating manual Ivy 2.0 945027 2 | Purpose of the manual Abbreviations Abbreviation Meaning Heat Memory System Stoves...
  • Page 8: Safety

    3 | Safety Operating manual Ivy 2.0 945027 Safety In this manual we give you numerous safety instructions for the safe operation of your stove. These in- structions are characterized differently as follows, depending on their importance: Importance of the safety instructions NOTICE Particular behaviour and/or activities that are required for safe working.
  • Page 9: Special Types Of Danger And Personal Protective Equipment

    Operating manual Ivy 2.0 945027 3 | Safety • Please note that the surfaces of this stove heat up considerably during operation. We recommend that you use the protective glove supplied to operate your stove. • Please alert children to these dangers, and keep them away from the stove when it is operating.
  • Page 10: Product Overview

    Operating manual Ivy 2.0 945027 Product overview Intended use The Austroflamm stove described in this manual is manufactured and tested with a type A1 self-closing and locking door under EN test EN 13240. NOTICE Operation is only permissible with closed/bolted door.
  • Page 11 Operating manual Ivy 2.0 945027 4 | Product overview 1) Open (+) and closed (-) (primary/secondary air control- ler) Fig. 2: Air control Safety distances Fig. 3: Safety distances (view from above)
  • Page 12: Energy Label

    4 | Product overview Operating manual Ivy 2.0 945027 Energy label -80% Austrof amm -60% -40% -20% ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI 2015/1186 Fig. 4: Energy label Positioning of the nameplates Here we show where you can find the nameplate. You can find a copy of the nameplate of your stove on the back of this manual.
  • Page 13: Technical Data

    Operating manual Ivy 2.0 945027 5 | Technical data Technical data As a type 1 stove, a connection to a chimney already occupied with other solid-fuel stoves and ovens is possible provided that the chimney rating under DIN 4705 – part 3, does not contravene this.
  • Page 14 5 | Technical data Operating manual Ivy 2.0 945027 Lignite briquettes Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 15: General Specifications

    Operating manual Ivy 2.0 945027 5 | Technical data Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec- tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let- ter a, section i, point 2 and 3.)
  • Page 16: Transport, Handling And Storage

    6 | Transport, handling and storage Operating manual Ivy 2.0 945027 Transport, handling and storage Transportation Immediately checked the goods delivered for complete- ness and damage in transit. Before installing the stove, check that all movable parts are working. Any defects before the installation of the stove must be reported.
  • Page 17: Storage

    Operating manual Ivy 2.0 945027 6 | Transport, handling and storage Storage The stove must be stored in a dry room/warehouse. Protect against dirt, heat and moisture. The following illustrations are attached to the crate and must be observed: • Fragile – always place upright – protect against moisture and store dry.
  • Page 18: Requirements At The Installation Location

    When connecting the flue pipes to the chimney, national and/or local safety regulations must be com- plied with. Your Austroflamm stove is fitted at the factory with a flue outlet at the top (diameter 130 mm). The connection can, as described in these instructions, be rearranged to the bottom. When con- necting with other pipe diameters the approval of your responsible chimney sweep is required.
  • Page 19: Fuel Material/-Quantity

    Operating manual Ivy 2.0 945027 8 | Fuel material/-quantity Fuel material/-quantity Fuel Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
  • Page 20 8 | Fuel material/-quantity Operating manual Ivy 2.0 945027 Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
  • Page 21: Fuel Quantity

    Maximum amount of fuel to be deposited: 1.5 kg wood or 1.3 kg briquettes. NOTICE Overheating Too great a quantity of fuel can lead to overheating and damage to your Austroflamm stove NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in...
  • Page 22: Installation

    9 | Installation Operating manual Ivy 2.0 945027 Installation Installation must only be carried out by an authorized specialist company. Before installing the stove, check that all movable parts are working. Any defects must be reported be- fore the installation.
  • Page 23 Operating manual Ivy 2.0 945027 9 | Installation 3) Remove cover with seal (1) on the back. 4) Remove bracket with seal (2). Fig. 10: Remove cover and bracket 5) Replace parts and reinstall. Fig. 11: Replacing cover and bracket...
  • Page 24: Installing The Hms

    9 | Installation Operating manual Ivy 2.0 945027 6) Reinstall the radiation protection and rear panel. Fig. 12: Installing the radiation protection and rear panel 9.2.2 Installing the HMS 1) Mount the HMS on the stove as depicted above and place the top box over the HMS bricks on top of it.
  • Page 25: Mounting The Keramott

    Operating manual Ivy 2.0 945027 9 | Installation 9.2.3 Mounting the Keramott Numbering = installation sequence Fig. 14: Keramott 9.2.4 Mounting the base 1) First remove the stove from the wooden base. Fig. 15: Remove the wooden base.
  • Page 26: Mounting The Side Box

    9 | Installation Operating manual Ivy 2.0 945027 2) Then mount the additional base (2) on top of the wooden base. 3) Insert the stove (3) into the base (2). Fig. 16: Mounting the base. 9.2.5 Mounting the side box 1) Insert the side box on the wooden base.
  • Page 27: Installing The Log Drawer

    Operating manual Ivy 2.0 945027 9 | Installation 3) Fasten the side box to the left and right of the stove. Fig. 19: Fastening the side box 9.2.6 Installing the log drawer 1) Slide the log drawer from the rail. Fig. 20: Sliding the log drawer from the rail 2) Mount the rail frame.
  • Page 28: Mounting The External Air Connection At The Rear

    9 | Installation Operating manual Ivy 2.0 945027 3) Insert the log drawer in the rail. Fig. 22: Inserting the log drawer in the rail 4) Attachment pins (1) must penetrate through the drawer. Fig. 23: Attachment pins 9.2.7 Mounting the external air connection at the rear 1) First dismantle the rear panel.
  • Page 29 Operating manual Ivy 2.0 945027 9 | Installation 3) First attach the clamp (2) on the air supply adapter (1). 4) Mount the air supply adapter (1) from the rear and fasten it with the clamp. Fig. 25: Mounting the air supply adapter.
  • Page 30: Settings

    10 | Settings Operating manual Ivy 2.0 945027 Settings 10.1 Adjusting the door 1) Open the doors and set the doors at the marked points 1, 2 and 3 as follows. Fig. 27: Adjusting the door • You can adjust the doors by turning these screws - for- ward, back, left and right - with a screwdriver.
  • Page 31: Adjusting The Door Spring

    Operating manual Ivy 2.0 945027 10 | Settings • Adjust the screw with a screwdriver (turn in or out). Fig. 30: Pos. 3 Adjusting the door 10.2 Adjusting the door spring 1) To adjust the door spring, the hob must be removed and only the left side cladding detached.
  • Page 32: Commissioning

    11 | Commissioning Operating manual Ivy 2.0 945027 Commissioning 11.1 Initial Commissioning NOTICE During the initial commissioning and in the following 2-3 combustion cycles, only approx. 2/3 of the maximum fuel quantity is to be used. NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in this manual! During the first 3-4 combustion cycles at nominal heat output, odors may develop.
  • Page 33: Operation

    Operating manual Ivy 2.0 945027 12 | Operation Operation 12.1 Before heating up The stove can only function properly if there is sufficient combustion air coming to the room of installa- tion (the appliance), specially if several firing installations are being operated at the same time. Ensure sufficient air supply before heating up.
  • Page 34: Heating In The Transition Period

    12 | Operation Operating manual Ivy 2.0 945027 7) Close the door. ð It is best to allow the first layer of wood to combust without altering the air damper setting. ð If only the bed of embers is left (no more flames), you can place another layer of log.
  • Page 35: Maintenance

    Operating manual Ivy 2.0 945027 13 | Maintenance Maintenance 13.1 Changing the seal on the door 1) Remove old seal from the door. 2) Glue in new seal with a suitable adhesive (e.g. silicon B310). ð Repeat these steps for the other door as well.
  • Page 36: Cleaning

    14 | Cleaning Operating manual Ivy 2.0 945027 Cleaning 14.1 Cleaning the stove, flue gas ducts and flue pipe The stove, the flue gas ducts and flues should be annually - possible even more often, e.g. • after the chimney has been cleaned •...
  • Page 37 Operating manual Ivy 2.0 945027 14 | Cleaning 3) Take the supplied cover and use it to cover the ash box. 4) Turn the handle of the cover clockwise until the handle engages. Fig. 37: Putting the cover on the ash box Fig. 38: Closing the cover...
  • Page 38: Cleaning The Door Window

    14.3 Cleaning the door window Spray window with glass cleaner and leave it for a moment to take effect. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner. • Prevent door- or window seals from coming into contact with water or cleaner, since these will oth- erwise harden and in doing so lose their function.
  • Page 39: Help

    Operating manual Ivy 2.0 945027 15 | Help Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss extend chimney/measure...
  • Page 40: Firebox Lining

    15 | Help Operating manual Ivy 2.0 945027 Problem Cause Solution Operating temperature not reached Bring stove to the operating temper- ature Sooting up of the window after 8- 10 hours of fires is normal Chimney draft too low Contact chimney sweep 15.1 Firebox lining...
  • Page 41: Accessories

    Operating manual Ivy 2.0 945027 16 | Accessories Accessories Have defective parts (accessories, spare parts) replaced by your specialist stove dealer. This guaran- tees that stove is and remains safe and functional.
  • Page 42: Spare Parts

    17 | Spare parts Operating manual Ivy 2.0 945027 Spare parts Accessories Pos. No. Quantity Item Article No. Elbow piece 130 Dexter Air supply adapter AH complete 074002-29 Base 078002-29 Side box right/left 078003-29 (Conversion option for installation left) Top box 078004-29 HMS complete (only with top box Pos.
  • Page 43 Operating manual Ivy 2.0 945027 17 | Spare parts Keramott Item no. Quantity Item Article No. Keramott floor left 726273 Keramott floor rear 726276 Keramott floor left 726373 Keramott floor front 727274 Keramott panel rear left 727277 Keramott panel rear right...
  • Page 44 17 | Spare parts Operating manual Ivy 2.0 945027 Firebox window Item no. Quantity Item Article No. Gasket 8x2x1600 CULIMETA 710096 Gasket 8x0.8x1600, self-adhesive CULIMETA 718767 008 Window glass for firebox window 727258 Hexagon nut with flange, M4 DIN6923 718739-92...
  • Page 45: Dismantling

    Operating manual Ivy 2.0 945027 18 | Dismantling Dismantling For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. 18.1 Removing the rear panel 1) Loosen the screws on the rear panel. Fig. 40: Loosening the screws 2) Then press the rear panel upwards and remove it.
  • Page 46: Removing The Door

    18 | Dismantling Operating manual Ivy 2.0 945027 18.2 Removing the door 1) Open the door and loosen the screws. Fig. 42: Opening the door and loosening the screws 2) Press the hinge plate (1) out and unhinge the door (2).
  • Page 47: Disposal

    NOTICE For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them. These com- ponents must not be disposed of via non-recyclable waste.
  • Page 48 19 | Disposal Operating manual Ivy 2.0 945027 Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
  • Page 49: Guarantee / Warranty

    For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commissioning. In or- der to make a claim on the warranty, repairs to your stove must only be carried out by a service en- gineer authorized by Austroflamm.
  • Page 50: Data Processing

    If you consent to the appropriate handling of your personal data for the following purposes, please tick this box. o I hereby agree that Austroflamm GmbH and AUSTROFLAMM Service GmbH & Co KG may send me service reminders and offers on other products from Austroflamm GmbH for the purposes of advert- ising via E-Mail/ SMS/ telephone.
  • Page 51: Start Up Log

    Operating manual Ivy 2.0 945027 22 | Start up log Start up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Stove Working Comments Model Serial number...
  • Page 52: Service Report

    23 | Service Report Operating manual Ivy 2.0 945027 Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 53 Operating manual Ivy 2.0 945027 23 | Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 54 Notizen / notes / appunti / remarques...
  • Page 55 Notizen / notes / appunti / remarques...
  • Page 56 Vollständigkeit / completeness / completo / complet Geprüft von / checked by / controlled da / contrôlé par ____________________________________________________ Datum / date / data / date ____________________________________________________ AUSTROFLAMM GMBH Austroflamm-Platz 1 A- 4631 Krenglbach Tel: +43 (0) 7249 / 46 443 www.austroflamm.com...

Table of Contents