Page 1
Operating manual Uno Xtra www.austroflamm.com...
Page 2
Printing, spelling and typographical errors reserved. The information in this document is subject to change without prior notice and should not be construed as a commitment by Austroflamm GmbH. Austroflamm GmbH assumes no responsibility for any errors that may appear in this document.
Operating manual Uno Xtra Contents Contents General information ............................Copyright.............................. Information about the document ...................... Purpose of the manual............................Storing the manual ..........................Structure of the manual........................Representations used.......................... Version control ............................. Abbreviations ............................Safety..................................Importance of the safety instructions ....................
Page 4
Contents Operating manual Uno Xtra 9.1.3 Converting external air connection....................26 9.1.4 Installing the HMS..........................27 9.1.5 Mounting the cladding ........................30 9.1.6 Mounting the fan and cover ....................... 31 10 Settings ................................. 32 10.1 Aligning the stove..........................32 10.2 Adjusting the door ..........................
Information about the document The information in this document is subject to change without prior notice and should not be con- strued as a commitment by Austroflamm GmbH. Austroflamm GmbH assumes no responsibility for any errors that may appear in this document.
2 | Purpose of the manual Operating manual Uno Xtra Purpose of the manual This manual is a component part of the stove and is intended to contribute to the stove being safely in- stalled and maintained. Please read this manual before using the stove for the first time.
• Before operating your stove, carefully read through the entire manual and observe the instructions and warnings. • Austroflamm GmbH accepts no liability or responsibility for the connection of our heating appli- ances to shared exhaust pipes/chimneys – multiple occupancy. For more information consult a chimney sweep and check your national, regional and local building regulations.
Operating manual Uno Xtra 3 | Safety • Please note that the surfaces of this stove heat up considerably during operation. We recommend that you use the protective glove supplied to operate your stove. • Please alert children to these dangers, and keep them away from the stove when it is operating.
4 | Product overview Operating manual Uno Xtra Product overview Intended use The Austroflamm stove described in this manual is manufactured and tested with a type A1 self-closing and locking door under EN 13240. NOTICE Operation is only permissible with closed/bolted door.
Page 11
Operating manual Uno Xtra 4 | Product overview Safety distances Fig. 2: Safety distances (view from above) up 1) Open (+) and closed (-) convection air controller 2) Open (+) and closed (-) grate scraper 3) Open (+) and closed (-) primary/secondary air control-...
4 | Product overview Operating manual Uno Xtra Energy label -80% Austrof amm Uno Xtra -60% -40% -20% ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI 2015/1186 Fig. 4: Energy label Positioning of the type plate Here we show where you can find the type plate.
Operating manual Uno Xtra 5 | Technical data Technical data As a type 1 stove, a connection to a chimney already occupied with other solid-fuel stoves and ovens is possible provided that the chimney rating under DIN 4705 – part 3, does not contravene this.
Page 14
5 | Technical data Operating manual Uno Xtra Particular precautions for assembly, installation or maintenance Described in the individual sections of the operating manual. Fuel Preferred Other suit- ηs Space heating emis- Space heating emis- fuel able fuel(s) [x%]: sions at nominal heating...
Page 15
Operating manual Uno Xtra 5 | Technical data Properties for exclusive operation with the preferred fuels Specification Symbol Value Unit Specification Symbol Value Unit Heat output Thermal efficiency (fuel efficiency) (based on the NCV) Nominal heat effi- Pnom Thermal efficiency (fuel ef- 80.1...
Operating manual Uno Xtra 6 | Transport, handling and storage Transport, handling and storage Transportation Immediately checked the goods delivered for complete- ness and damage in transit. Before installing the stove, check that all movable parts are working. Any defects before the installation of the stove must be reported.
When connecting the flue pipes to the chimney, national and/or local safety regulations must be com- plied with. Your Austroflamm stove is fitted at the factory with a flue pipe outlet at the top (see chapter Technical data). The connection can, as described in these instructions, be rearranged to the bottom.
Floor condition Austroflamm stoves can be placed directly on the floor. The fire protection regulations for operating a wood-burning or pellet stove vary depending upon the location and appliance. We recommend you obtain this information from your chimney sweep or the specialist dealer in your area.
8 | Fuel material/-quantity Operating manual Uno Xtra Fuel material/-quantity Fuel Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
Page 21
Operating manual Uno Xtra 8 | Fuel material/-quantity Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
Maximum amount of fuel to be deposited: 2.0 kg wood. NOTICE Overheating Too great a quantity of fuel can lead to overheating and damage to your Austroflamm stove NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in...
Operating manual Uno Xtra 9 | Installation Installation Installation must only be carried out by an authorized specialist company. Before installing the stove, check that all movable parts are working. Any defects must be reported be- fore the installation. In the following sections we will give you information on •...
9 | Installation Operating manual Uno Xtra Execution 9.1.1 Rearranging the flue pipe connection 1) First the cover, the rear panel and the side cladding must be removed. Proceed as described in the sec- tion Removing side cladding [}on page 44].
9 | Installation Operating manual Uno Xtra 9.1.3 Converting external air connection 1) First the cover, the rear panel and the side cladding must be removed. Proceed as described in the sec- tion Removing side cladding [}on page 44]. 2) Using a saw, remove the perforated cut-out to the side cladding (rear).
Operating manual Uno Xtra 9 | Installation 9.1.4 Installing the HMS 1) First the cover, the rear panel and the side cladding must be removed. Proceed as described in the sec- tion Removing side cladding [}on page 44]. 2) Unscrew dummy plugs.
Page 28
9 | Installation Operating manual Uno Xtra 5) Position the HMS bricks so that they lay flat against the firebox walls and rest on the HMS sheets. 6) Use the screw connection (washer / screw) to screw each one in once.
Page 29
Operating manual Uno Xtra 9 | Installation 8) Position HMS bricks at the top. Fig. 20: Positioning the HMS bricks at the 9) Fix the HMS bricks at the top by turning the turn- buckle. Fig. 21: Fixing the HMS bricks at the top...
9 | Installation Operating manual Uno Xtra 9.1.5 Mounting the cladding The assembly described for the side cladding is the same for all versions of the side cladding. 1) Hang the side cladding (left + right) on the screw heads.
Operating manual Uno Xtra 9 | Installation 9.1.6 Mounting the fan and cover 1) Use the screws to fix the fan. Fig. 23: Assemble fan 2) Finally, attach the cover. Fig. 24: Attaching the cover...
10 | Settings Operating manual Uno Xtra Settings 10.1 Aligning the stove 1) First the cover and the side cladding must be de- tached. ð Proceed as described in the section Removing the side cladding. 2) There are two screw on the back of the stove. These can be used to align the stove.
Operating manual Uno Xtra 10 | Settings 10.3 Adjusting the door lock 1) Open the door. Fig. 28: Opening the door 2) Using the marked screws the door lock can be adjus- ted forwards and backwards. Fig. 29: Adjusting the door lock 3) The rabbet for the door handle can be adjusted using the screws.
11 | Commissioning Operating manual Uno Xtra Commissioning 11.1 Initial Commissioning NOTICE During the initial commissioning and in the following 2-3 combustion cycles, only approx. 2/3 of the maximum fuel quantity is to be used. NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in this manual! During the first 3-4 combustion cycles at nominal heat output, odors may develop.
Operating manual Uno Xtra 12 | Operation Operation 12.1 Before heating up The stove can only function properly if there is sufficient combustion air coming to the room of installa- tion (the appliance), specially if several firing installations are being operated at the same time. Ensure sufficient air supply before heating up.
12 | Operation Operating manual Uno Xtra 9) As soon as the pieces of firewood are burning well all around (light, high flames), you can control the air supply with the controller. ð Control at maximum setting = maximum heat out- ð...
14 | Cleaning Operating manual Uno Xtra Cleaning 14.1 Cleaning the stove, flue gas ducts and flue pipe The stove, the flue gas ducts and flues should be annually - possible even more often, e.g. • after the chimney has been cleaned •...
14.4 Cleaning the door window Spray window with glass cleaner and leave it for a moment to take effect. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner. • Prevent door- or window seals from coming into contact with water or cleaner, since these will oth- erwise harden and in doing so lose their function.
15 | Help Operating manual Uno Xtra Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss extend chimney/measure...
Operating manual Uno Xtra 15 | Help Problem Cause Solution Operating temperature not reached Bring stove to the operating temper- ature Sooting up of the window after 8- 10 hours of fires is normal Chimney draft too low Contact chimney sweep 15.1 Firebox lining...
16 | Accessories Operating manual Uno Xtra Accessories Have defective parts (accessories, spare parts) replaced by your specialist stove dealer. This guaran- tees that stove is and remains safe and functional. Item no. Quantity Article Article no. Basic appliance 063001...
18 | Dismantling Operating manual Uno Xtra Dismantling For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. 18.1 Removing side cladding 1) Detach cover (if mounted). Fig. 36: Detaching the cover 2) Undo the screws. 3) Dismount fan.
Page 45
Operating manual Uno Xtra 18 | Dismantling 4) Lift up and detach the side cladding. Fig. 38: Detaching the side cladding 5) Lift and detach the rear panel. Fig. 39: Removing the rear panel...
18 | Dismantling Operating manual Uno Xtra 18.2 Removing the HMS 1) To remove the cover and the side cladding, Proceed as described in the section Removing the side clad- ding. DANGER Tilt hazard Before the HMS bricks are removed, it must be ensured that the stove does not tip forward.
Page 47
Operating manual Uno Xtra 18 | Dismantling 4) Undo the screws and dismount the HMS bricks on the sides. Fig. 42: Dismounting the HMS bricks at the sides 5) Only loosen the screw at the back and dismount the HMS bricks at the back.
NOTICE For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them. These com- ponents must not be disposed of via non-recyclable waste.
Page 49
Operating manual Uno Xtra 19 | Disposal Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commissioning. In or- der to make a claim on the warranty, repairs to your stove must only be carried out by a service en- gineer authorized by Austroflamm.
Operating manual Uno Xtra 21 | Start up log Start up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Stove Working Comments Model Serial number...