4-1-5. Level Adjustment of Machine
Using 4 sets of M16*20 bolts and nuts, plus 4 pieces of hard material underneath the machine base to
adjust level.
a. Level instrument shall be placed according to following drawing:
b. Required tool and cautions as follows:
1. Precise level instrument x 2
2. M16*2.0*50 x 4 bolts and nuts for fixing purpose
3. 24mm open wrench
4. 4 pieces of pad, Length 50mm, width 50mm, thickness 10mm
5. In the case of unstable base, level calibration must be done biyearly.