Electrical installation of the power cabinet
Procedure
1. Attach the PE cable (A) to the PE busbar (B).
with a loop.Use the fasteners (D).
The loop is necessary to make sure
that the PE cable is not the first
wire that is disconnected when a
collision moves the charge post.
2. Tighten the fasteners to the correct torque.
7.3
Connect the AC power cables in the power cabinet
Preliminary requirements
Procedure
1. Attach the AC cables to the AC bus-
bars. Use the fasteners (D).
2. Tighten the fasteners to the correct
torque. For the specification, refer
to section 12.13.
3. Reinstall the protective cover (F) by
screwing the 2 fasteners.
46
For the specification, refer to section 12.13.
Wire stripper pliers
Wire cutter
Torque wrench
Cable lug
Fasteners M11
D
B
A
6AGA000032-0115-EN | 004
B
A
E
D
C
F