Connect A Wire That Has A Cable Lug; Connect A Wire That Has A Ferrule - ABB Terra HP Generation 4 CE Ionity Installation Manual

Table of Contents

Advertisement

Generic procedures
11.4

Connect a wire that has a cable lug

Preliminary requirements
Procedure
1. Loosen the bolt of the connection pin
(A) on the busbar (B).
2. Install the eye of the cable lug (C) on
the connection pin.
3. Tighten the bolt of the connection pin
on the busbar to the correct torque.
For the torque specification, refer to
section 12.13.
4. Make sure that unused wires are
protected and cannot touch metal
parts.
11.5

Connect a wire that has a ferrule

Preliminary requirements
Procedure
1. Loosen the screw of the connection on
the terminal.
2. Install the ferrule in the connection of
the terminal.
3. Tighten the screw to the correct
torque. For the specifications, refer to
section 12.13.
4. Make sure that unused wires are
protected and cannot touch metal
parts.
66
Torque screwdriver, cross
B
A
3
B
2
6AGA000032-0115-EN | 004
C
A
1

Advertisement