8.7

Pre-commissioning mode

If it is not possible to complete commissioning because it is not possible to supply
the power cabinet from the main power line, it is necessary to set the charger in
"precommissioning mode". In this way it is possible to avoid condensation
phenomena inside the charger.
Preliminary requirements
Procedure
1. Strip the insulation from the ends of
the wires (A) to (C).
2. Crimp ferrules onto the end of
the wires. Refer to section
Obey the ferrule manufacturer
recommendations.
3. Loosen the screws of the terminal
block X-1.
4. Connect these wires:
5. Tighten the screws to the correct torque. For the specification, refer to section
12.13.
6. Turn on the switch Q1 of the charge post
7. Turn on the switches Q2, Q3 and Q4 of the
power cabinet
8. Set the precommissioning selector on the
6AGA000032-0115-EN | 004
Torque screwdriver, cross
Wire cutter
Wire stripper pliers
Crimp pliers
AC single-phase cable.
Refer to section
Ferrules
For the procedure, refer to section
11.2.
For the specification, refer to
section
12.18.4.
Line wire (A), brown, to the terminal X1-1 (D)
Neutral wire (B), blue, to the terminal X1-2 (E)
PE wire (C), green/yellow, to the terminal X1-3 (F)
posizion 1 (EXT)
Electrical installation of the charge post
12.18.4.
11.2.
D
E
F
A
B
C
H1
X21
EXT
INT
0
1
2
Q10