Ac Auxiliary Power Cables; Interlock And Dc Guard Cables - ABB Terra HP Generation 4 CE Ionity Installation Manual

Table of Contents

Advertisement

Technical data
Parameter
Conductor
Insulation
Minimum nominal voltage Uo/U
Minimum test voltage
Ambient temperature range
Diameter of the PE conductor
12.18.4

AC auxiliary power cables

Parameter
Number of cores
Cross section range
Shielding
Conductor
Insulation
Minimum nominal voltage (Uo/U)
Minimum test voltage (AC)
Ambient temperature range
Core identification
Strip length
12.18.5

Interlock and DC guard cables

Parameter
Number of cores
Diameter (inside)
Diameter (outside)
Shielding
Conductor
Insulation
Test voltage
Strip length
94
Specification
Fine strand copper wire according to
VDE 0295 Cl. 5/ IEC 60228 Cl. 5
Special PVC that is serviceable for out-
door use, UV-protected, and oil resistant
600/1000 Vac
4 kV
-40°C to 80°C (-40 °F to +176 °F)
The same as the diameter of the phase
conductors
Specification
4
2.5 mm² (14 AWG)
No
Bare copper, fine wired, brunch stranded
according to VDE 0295 CI.5/IEC CI.5
Special PVC ( that is serviceable for out-
door use, UV-protected, and oil resistant
450/750 Vac
4 kV
-40°C to +80°C (-40 °F to +176 °F)
According to IEC 60446
11 mm (0.43 in)
Specification
2 x 2 twisted pair (4 core)
1.3 to 2.1 mm² (16 to 14 AWG)
10 to 17 mm (0.39 to 0.67 in)
Tinned copper braid
Possible configuration: shielded 4 core
cable 2 x 2 pairs twisted or two separate
shielded dual core cables
Fine strand copper wire
PVC or other material that is serviceable
for outdoor use and UV-protected
1.5 kV
11 mm (0.43 in)
6AGA000032-0115-EN | 004