Connect The Dc Power Input Cables - ABB Terra HP Generation 4 CE Ionity Installation Manual

Table of Contents

Advertisement

Electrical installation of the charge post
b. Strip the insulation from the end
c. Attach the cable lug (C) to the end
2. Attach the PE wire to the PE busbar.
Use the fasteners (D).
3. Tighten the fasteners to the correct torque.
For the specification, refer to section 12.13.
8.3

Connect the DC power input cables

Preliminary requirements
Procedure
1. Cut the DC power cables
(A) and (B) to make sure
that the length is sufficient
for connection at the DC
busbars (C) and (D).
2. Strip the insulation from the
end of the cables. Make
sure that the strip length
is compatible with the cable
lugs.
3. Attach the cable lugs to the
end of the cables.
4. Remove the nuts and
washers (E) from the
connector bolts (F1) and (G1)
of the DC busbars.
5. Connect these cables:
6. If you need to connect more DC cables, do steps 4 and 5 again for the other
wires and connector bolts (F2) and (G2).
7. Install the nuts and washers on the connector bolts of the DC busbars.
8. Tighten the nuts to the correct torque. For the specification, refer to section
12.13.
52
of the wire. Make sure that the
strip length is compatible with the
cable lug.
of the wire.
Wire cutter
Wire stripper pliers
Spanner
Torque wrench
Torque screwdriver, cross
DC power cable. Refer to
section 12.18.2.
Cable lugs. Refer to section
12.4.
DC+ cable (A) to the connector bolt (F1).
DC- cable (B) to the connector bolt (G1).
D
C
D
G2
G1
F1
B
E
6AGA000032-0115-EN | 004
B
A
C
F2
A