7.6
Connect the interlock and DC guard cables to the power
cabinet
Preliminary requirements
Procedure
1. Prepare ferrules for the wires that are
mentioned below. Refer to section 11.2.
2. Connect the below listed wires from the
charge post. Use the illustration above
as a reference:
6AGA000032-0115-EN | 004
•
Interlock and DC guard
cable. Refer to section
12.18.5.
Note: The illustration shows the terminal block X9 on the power cabinet
and the connections treated in this section. For a detailed overview of all
electrical connections, refer to section 12.19.
Wire from charge post
(A) Interlock OUT
(B) Interlock IN
(C) DC guard GND
(D) DC guard signal
(E) Ground wire or shield
mesh
Electrical installation of the power cabinet
•
-X4
Connect to terminal
X4-3
X4-4
X4-5
X4-6
Earthing terminal
A
B
C D
Terminal name
IN CL CP1
OUT CL CP1
DC1 GUARD
DC1 GUARD RTN
DC1 PE
E
49