Electrical Installation Of The Charge Post; General Procedure; Connect The Pe Cable - ABB Terra HP Generation 4 CE Ionity Installation Manual

Table of Contents

Advertisement

8

Electrical installation of the charge post

8.1

General procedure

Preliminary requirements
Procedure
1. Open the door of the charge post. Refer to section 10.6.
2. Remove the protection plate. Refer to section 10.8.
3. Connect the cables to the charge post:
4. Install the protection plate.
5. Close and lock the door of the charge post. Refer to section 10.11.
8.2

Connect the PE cable

Preliminary requirements
Procedure for each PE connection:
1. Prepare the wire:
a. Cut the PE wire (A) to make sure that the length is sufficient for connection
6AGA000032-0115-EN | 004
Note: For a detailed overview of all electrical connections, refer to
section 12.19.
The DC power cables are
installed in one of the
cable conduits. Refer to
section 12.17.
The other cables are
installed in the other cable
conduits. Refer to section
12.17.
PE wires. Refer to section
DC power cable. Refer to section
AC auxiliary power cable. Refer to section 8.4.
Interlock and DC guard cable. Refer to section
The door is open.
Wire stripper pliers
Torque socket wrench
at the PE busbar (B) with a loop.
The loop is necessary to make sure that the PE wire is not the first wire that
is disconnected when a collision moves the charge post.
Electrical installation of the charge post
8.2
8.3
8.5
Cable lug. Refer to section
12.4.
Fasteners M11. Refer to
section 12.4.
51

Advertisement

Table of Contents
loading

Table of Contents