Parameter
Input voltage range
Nominal input current
Maximum input current
Cores
Cross section range
Maximum input current
Power factor at full load
12.6.3

Requirements for charge post auxiliary

Parameter
Surge protection device
Power consumption
Earthing system
Input AC power connection
Input voltage range
Input current
Cores
Cross section range
Maximum input current
12.7

DC output specifications

Parameter
Output voltage range
Maximum output current
Output power
DC output current
Cores
Phases cross section range
Earth cross section range
Cable lug maximum width
6AGA000032-0115-EN | 004
Specification
230 V AC +/- 10 % (50 Hz or 60 Hz) Nomi-
nal input
550 A at 400 V AC
15 A at 230 V AC
According to IEC 60446
2
3 x 4 mm
20 A at 230 V AC
> 0.95
Specification
Type 2
In standby status: ≤ 1500 W
TN-C
TN-S
TN-CS
TT
400 / 230 V AC 3W + PE
400 V AC +/- 10 % (50 Hz or 60 Hz)
2 A at 380 V AC
According to IEC 60446
2
4 x 4 mm
3 A at 280 V AC
Specification
150 - 920 V DC
500 A DC
360 kW up to 40 °C (104 °F)
500 A CCS (liquid cooled)
according to IEC 60446 aluminum/ cop-
per
2
2 x 120 mm
to 180 mm
2
or 1 x 240 mm
to 300 mm
2
35 mm
40 mm, M12
Technical data
2
per pole
2
per pole
71