Overview Of The Cable Glands Of The Charge Post; Electric Vehicle Site Solution Control 202 (Evss); Tilt Sensor Supply - ABB Terra HP Generation 4 CE Ionity Installation Manual

Table of Contents

Advertisement

Description
3.5.8

Overview of the cable glands of the charge post

A
B
C
D
E
F
3.6

Electric Vehicle Site Solution Control 202 (EVSS)

The EVSS Control 202 basic functionality is the load management of an EV charging
site. It is managing the power consumed on a site and enables a centralized OCPP
connectivity gateway to the user's or CPO's backend. The EVSS Control 202 contains:
a Centralized connectivity to operator backend for OCPP traffic;
Local site power management to manage, distribute and monitor available
power/load of the site for each charger;
3.7

Tilt Sensor Supply

The Tilt Sensor Supply is a device to connect all wirings for the emergency circuits
described below:
Connecting circuits to enable LV circuit breaker tripping mechanism during
activation of tilt sensors within the Power Cabinets and Charge Posts;
Enabling the possibility to connect an emergency stop button (EMO);
Maximum twenty-four HP 360 Charger systems and one Terra 53/54 can be
connected to one EVSS Control 202 and Tilt Sensor Supply.
26
A
B
C
L
K
PE wire
AC auxiliary power cable
PE wire
PE wire
Ethernet cable
Not used
D
E
F
J
I
G
Interlock and DC guard cable
H
Ethernet cable
I
DC+ in cable
J
DC+ in cable
K
DC- in cable
L
DC- in cable
G
H
6AGA000032-0115-EN | 004

Advertisement

Table of Contents
loading

Table of Contents