Temperature Control - Ricoh Gestetner LANIER SAVIN G071 Service Manual

Table of Contents

Advertisement

6.9.3 TEMPERATURE CONTROL

The table lists default settings and variable ranges for temperature control.
External temperature
(*1)
Roller
Fusing idling start
(*2)
Print ready
(*3)
Ready (standby mode)
1
Energy saver
2
Mono color
Normal
paper
Full color
'>90
Mono color
g/m2, 24
Full color
lb
(*4)
Printing
Mono color
Thick
Full color
Mono color
OHP
Full color
Mono color
Duplex
(*5)
Full color
Variable range
(*6)
*1: External temperature is measured (temperature/humidity sensor) when the main switch is
turned on and when a job start signal is received.
*2: The pressure and heating rollers start idling.
*3: Fusing idling stops when both roller temperatures reach the print ready condition. The
printer can process jobs when the rollers reach this temperature during warm-up.
*4: A user tool (Paper Input – Paper Type) specifies the paper type in each tray (plain, thick, or
OHP). If 'plain' is selected, then either SP 5-945 (MidThickPaper) or another user tool
(Maintenance – Plain Paper Type) defines whether the paper in the tray is 'normal' or '>90
g/m2, 24 lb'. (! 5.2.2). '>90 g/m2, 24 lb' means 'greater than or equal to 90 g/m2, 24 lb'.
'Thick' means paper heavier than 105 g/m
*5: Both sides of the paper are processed with the same roller temperatures.
*6: Use SP1-105 (Fusing_Temp) to adjust the fusing temperatures (! 5.2.2).
SM
CÓPIA NÃO CONTROLADA
FUSING UNIT AND OIL SUPPLY UNIT
More than 15°C ~
less than 30°C
Heating
Press.
160
30
165
75
175
120
100
110
Room
Room
temp.
temp.
160
Lamp off
170
Lamp off
170
Lamp off
180
Lamp off
165
Lamp off
175
Lamp off
170
Lamp off
180
Lamp off
155
Lamp off
165
Lamp off
100 ~
30 ~ 200
190
2
(28 lb).
6-47
CÓPIA NÃO CONTROLADA
15°C or lower
30°C or higher
Heat.
Press.
Heat.
160
30
160
Heat.: +5
Heat.: –5
Adjustable with
Adjustable with
SP1-105-27
SP1-105-29
(Fusing_Temp -
(Fusing_Temp -
H: OFFSET+)
H: OFFSET-)
Press.: +0
Press.: +0
Adjustable with
Adjustable with
SP1-105-28
SP1-105-30
(Fusing_Temp -
(Fusing_Temp -
P: OFFSET+)
P: OFFSET-)
0 ~ +20
0 ~ –20
Press.
30
G071