Ricoh Gestetner LANIER SAVIN G071 Service Manual page 107

Table of Contents

Advertisement

The gradation scales marked 'Default' are printed according to the default gamma
settings in the flash ROM in the controller. The gamma adjustment changes the
densities at the adjustable points in the gradation scale. The gradation scale
marked "Current" shows the current settings.
During the adjustment procedure, compare the "Current" gradation scale with the
'Default'. Select the density for each of the 15 adjustable points, excluding points 0
and 255, from the 'Default' gradation scale.
The NVRAM holds three sets of controller gamma settings:
• Those saved this time: ToneCtlSet - Tone (Current)
• Those saved in the previous adjustment: ToneCtlSet - Tone (Prev)
• The factory settings: ToneCtlSet - Tone (Factory).
Adjustment Procedure
1. Enter the controller service mode.
2. Use the down arrow key to select "ToneCtlSet" (the second of the two) and
press the Enter key.
3. Use the up/down key to select the mode that requires calibrating, then press
the Escape key until you get back to the controller service mode menu.
4. Use the down arrow key to select "PrnColorSheet" and press the Enter key.
5. Use the up/down key to select "ToneCtlSheet" (normally this is displayed by
default) and press the Enter key.
6. When "Execute?" is displayed, press the Enter key to print out the "color
calibration test sheet".
7. When "Execute OK" is displayed, press the Escape key 2 times to exit from the
menu. (You return to "PrnColorSheet" in the controller service menu.)
8. Use the down arrow key to select "ToneCtlValue" and press the enter key.
SM
CÓPIA NÃO CONTROLADA
5-9
CÓPIA NÃO CONTROLADA
SP MODE TABLES