Ricoh Gestetner LANIER SAVIN G071 Service Manual page 129

Table of Contents

Advertisement

Rev. 04/2003
Mode No.
3
(Class 1, 2, and 3)
942
OPC_Ide_E_Svr
1
Idling_Time
2
PrintingReady
970
ImgAreaRate
1
M
2
C
3
Y
4
Bk
971
AutoTnrConsume
1
AutoTnrConsume
980
EmptyRev(Bk)
1
EmptyRev(Bk)
SM
CÓPIA NÃO CONTROLADA
The image transfer belt has curl tendency after long
period without rotation.
The image transfer belt tends to curl after a long period
without rotation.
To correct this, image transfer belt idling is done if the
fusing temperature is not high enough to print when
returning from energy saver mode.
This SP determines how long the idling rotation is done.
[3 ~ 5 / 3 / 1 minute/step]
Select when the machine can accept a print job after the
idling starts.
• 0: Immediately
• 1: After idling has been done for 1 minute
• 2: After idling finishes.
[0 ~ 2 / 0 / 1/step]
Specifies the minimum image area (expressed as a
percentage of an A4 page) required to maintain optimum
development unit condition (
SP3–971 [AutoTnrConsume]).
[0 ~ 10.0 / 2.0 / 0.1 %/step]
After 20 sheets over a number of small jobs (or after 50
sheets in one job), if the developed area is less than the
value of this SP mode, toner is transferred to the image
transfer belt and cleaned off. This is performed during
the doctor roller reverse rotation.
[0.0 ~ 10.0 / 2.0 / 0.1 %/step]
[0.0 ~ 10.0 / 2.0 / 0.1 %/step]
[0.0 ~ 10.0 / 3.0 / 0.1 %/step]
Enables/disables the toner revitalization.
[0 or 2 / 2 / 1 /step]
• 0: Disables
• 2: Enables
Continuous printing with a relatively low coverage ratio
(CMYK less than 5% each) tends to reduce the charge
potential of the toner, because the toner remains in the
hopper for a long time. This can lead to spots on the
copy. Toner revitalization removes this defective toner
periodically.
Activates/deactivates 1-color idling after paper transfer.
[0 ~ 1 / 0 / 1/step]
• 0: Deactivates
• 1: Activates
Set this to 1 if the user complains about diagonal lines in
solid areas of prints that only use one toner color (M, C,
or Y). It is especially noticeable in black areas.
5-31
CÓPIA NÃO CONTROLADA
SP MODE TABLES
Function / [ Setting ]
Toner Revitalization:
G071

Advertisement

Table of Contents
loading

Table of Contents