Ricoh Gestetner LANIER SAVIN G071 Service Manual page 111

Table of Contents

Advertisement

Rev. 04/2003
1
(Class 1, 2, and 3)
105*
16
P: _Standby
27
H: OFFSET+
28
P: OFFSET+
29
H: OFFSET–
30
P: OFFSET–
106
Temp._Display
1
H_Roller
2
P_Roller
109
Fusing_Nip
1
ExecuteMode
2
Stop_Duration
902*
PaperSize
1
B4/LG
2
A3/DLT
SM
CÓPIA NÃO CONTROLADA
Mode No.
Sets the pressure roller temperature for the ready
(standby) condition. After the main switch has been
turned on, the machine enters this condition when the
pressure roller temperature reaches the temperature
specified in this SP mode. When the machine is
recovering from energy saver or auto off mode, the
machine becomes ready when both heat and pressure
roller temperatures reach the specified temperature.
Heating roller: SP1-105-3
[60 ~ 150 / 110 / 1°C/step]
Sets the heating roller temperature correction for when
room temperature is 15°C or lower.
[0 ~ 20 / 5 / 1°C/step]
Sets the pressure roller temperature correction for when
room temperature is 15°C or lower.
[0 ~ 20 / 0 / 1°C/step]
Sets the heating roller temperature correction for when
room temperature is 30°C or higher.
[0 ~ 20 / 5 / 1°C/step]
Sets the pressure roller temperature correction for when
room temperature is 30°C or higher.
[0 ~ 20 / 0 / 1°C/step]
Displays the current temperature of the heating or
pressure roller.
[0 ~ 255 / 0 / 1/step]
Checks the fusing nip width using an OHP sheet.
[0 ~ 1 / 0 / 1/step]
• The OHP sheet stops in the fusing unit for the
specified time (
• The nip width should be 9 ± 0.5 mm at front and rear.
If this requirement is not met, change the fusing unit.
Adjusts the stoppage time for the OHP sheet in the
fusing unit (
[0 ~ 100 / 10 / 1 s/step]
Specifies how the machine interprets the paper size
sensor output for the main unit tray.
[0 ~ 1 / 0 / 1/step]
• For Europe:
0: B4 SEF, 1: LG SEF
• For N. America:
0: LG SEF, 1: B4 SEF
Specifies how the machine interprets the paper size
sensor output for the main unit tray.
[0 ~ 1 / 0 / 1 /step]
• For Europe:
0: A3 SEF, 1: DLT SEF
• For N. America:
0: DLT SEF, 1: A3 SEF
CÓPIA NÃO CONTROLADA
Function / [ Setting ]
SP1-109-2).
SP1-109-1).
5-13
SP MODE TABLES
G071