Advertisement

Rev. 01/2004
Mode No.
2
(Class 1, 2, and 3)
402*
ClnBiasNN1
1
1C
2
2C-4C
3
HalfSpeed/1C
4
HalfSpeed/2C-4C
5
Ppattern
6
NoImageArea
7
JamRecovery
8
OPC Lubrication Time
403*
ClnBiasNN2
1
1C
2
2C-4C
3
HalfSpeed/1C
4
HalfSpeed/2C-4C
5
Ppattern
6
NoImageArea
7
JamRecovery
8
OPC Lubrication Time
404*
ClnBiasHH
1
1C
2
2C-4C
3
HalfSpeed/1C
4
HalfSpeed/2C-4C
5
Ppattern
6
NoImageArea
7
JamRecovery
8
OPC Lubrication Time
500*
FusingBias (Discharge pin)
1
Nrml/1C/1st
2
Nrml/1C/2nd
3
Nrml/FC/1st
4
Nrml/FC/2nd
5
Thk/1C/1st
6
Thk/1C/2nd
7
Thk/FC/1st
8
Thk/FC/2nd
SM
CÓPIA NÃO CONTROLADA
Adjusts the transfer belt cleaning bias voltage when
absolute humidity AH (g/m
8.0 < AH ≤ 14 (this is the 'NN1' humidity range) DFU
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step] ** See page 5-22
Adjusts the transfer belt cleaning bias voltage when
absolute humidity AH (g/m
14 < AH ≤ 19 (this is the 'NN2' humidity range) DFU
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step] ** See page 5-22
Adjusts the transfer belt cleaning bias voltage when
absolute humidity AH (g/m
19 < AH (this is the 'HH' humidity range) DFU
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1700 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step] ** See page 5-22
Adjusts the discharge pin voltage (paper separation) and
fusing bias voltage. DFU
[4000 ~ 1000 / 3000 / 100 Volt/step]
• Same bias voltage is applied to the fusing unit and the
discharge pin.
[4000 ~ 1000 / 3000 / 100 Volt/step]
[4000 ~ 1000 / 2500 / 100 Volt/step]
[4000 ~ 1000 / 2500 / 100 Volt/step]
[4000 ~ 1000 / 3000 / 100 Volt/step]
[4000 ~ 1000 / 3000 / 100 Volt/step]
[4000 ~ 1000 / 2500 / 100 Volt/step]
[4000 ~ 1000 / 2500 / 100 Volt/step]
5-23
CÓPIA NÃO CONTROLADA
SP MODE TABLES
Function / [ Setting ]
3
) is in the following range:
3
) is in the following range:
3
) is in the following range: