Ricoh Gestetner LANIER SAVIN G071 Service Manual page 126

Table of Contents

Advertisement

SP MODE TABLES
Mode No.
2
(Class 1, 2, and 3)
950
4
K(2:P1b)
5
M(1:P1b)
6
C(1:P1b)
7
Y(1:P1b)
8
K(1:P1b)
9
M(P1a)
10
C(P1a)
11
Y(P1a)
12
K(P1a)
951
Image Position Adjustment
1
Mode
960 *
Tray_Heater
1
Tray_Heater
970
OilClearMode
1
Mode
2
Print_Int
3
Repetition_Num
4
Dup_Sheets
1
Mode
G071
CÓPIA NÃO CONTROLADA
[–3 ~ 3 / 0 / 2 line/step]
[–3 ~ 3 / –1 / 2 line/step]
[–3 ~ 3 / 0 / 2 line/step]
[–3 ~ 3 / 0 / 2 line/step]
[–3 ~ 3 / 0 / 2 line/step]
For use in Japan only.
[–3 ~ 3 / 0 / 2 line/step]
0: New PCU: ITB cleaning blade:
1: Old PCU: No ITB cleaning blade (Default): DFU
Optional tray heaters installed or not
[0 ~ 1 / 0 / 1/step]
0: No
1: Yes
Enables/disables the settings of SP2–970–2 through 4.
[0 ~ 1 / 1 / 1 /step]
• 0: Does not clear
• 1: Clears
Oil on duplex copies gets on the transfer belt, and this
can cause uneven image density. To remove this oil,
printing stops, the PCU turns, and the cleaning unit
removes the oil.
Enables/disables interruption of the oil removal process.
[0 ~ 1 / 0 / 1 /step]
• 0: Users cannot interrupt
• 1: Users can interrupt
If interruption is enabled, the user does not need to wait
until the oil removal process ends, but the output image
may be poor.
Specifies how many times the oil removal process is
repeated.
[1 ~ 20 / 5 / 1 /step]
The more times the oil removal is repeated, the better
the output images are; but the longer it takes
Specifies how often the oil removal process is done. The
unit is the number of duplex prints. The counter counts
down once every narrow (A4 SEF or less) duplex sheet,
and counts back up 1 for every other type of sheet.
[1 ~ 50 / 10 / 1 /step]
Sets whether or not lubrication is applied at Toner End
recovery.
0: OFF
1: ON (Default)
5-28
CÓPIA NÃO CONTROLADA
Function / [ Setting ]
Rev. 01/2004
SM

Advertisement

Table of Contents
loading