Mode No.
2
(Class 1, 2, and 3)
905
Paper Transfer Roller Type
1
Old/New Transfer
Roller Type
912
Temp_HumDisp
1
Temp
2
Humidity_1
3
Humidity_2
4
EnvLevel
917
Test Pattern
1
Test Pattern
920
ITB Cleaning Clutch OFF Time
1
Mode
921
ITB Cleaning Clutch OFF Mode
1
Mode
922
Development Clutch ON after Job End
1
Mode
923
Lubricant after Toner End
1
Mode
SM
CÓPIA NÃO CONTROLADA
This SP has add with firmware version V2.18 (1st
release) due to the shape modification to the paper
transfer roller to increase transferability.
When updating from V2.18 toV2.19 or later, please
check SP2-310-001 thru SP2-314-032 (paper transfer
currents) and SP2-903-01 (paper transfer Adjustment)
as the defaults for these values have been changed.
0: New paper transfer roller type (Drum Type)
1: Old paper transfer roller type (straight type)
Displays the temperature measured by the temperature
sensor inside the machine.
[–127 ~ 127 / 0 / 1°C/step]
Displays the humidity measured by the humidity sensor
inside the machine.
Displays the absolute humidity calculated from the
temperature/humidity sensor readings.
[0 ~ 65535 / 0 / 0.1 g/m
Displays the current humidity level calculated from the
absolute humidity.
[0 ~ 1 / 0 / 1/step]
• LL1: 0 < AH
• LL2: 3.5 < AH
• NN1: 8.0 < AH
• NN2: 14 < AH
• HH: 19 < AH
Allows you to print out the test pattern.
[0 ~ 1 / 0 / 1/step]
• 1: Print out the test patterns listed in SP5-955 (Test
Pattern – Pattern).
To print the selected chart, change the setting from 0 to
1, then print out the demo sheet (user tool) or send a
print job from a PC.
[-500 ~ 500 / 0 / 10 /step]
0: New PCU: ITB cleaning blade
1: Old PCU: No ITB cleaning blade (Default) : DFU
Determines whether or not a small amount of toner is
applied to the OPC belt surface in order to ensure proper
belt cleaning.
0: OFF
1: ON (Default)
Sets whether or not lubrication is applied at Toner End
recovery.
0: OFF
1: ON (Default)
5-25
CÓPIA NÃO CONTROLADA
SP MODE TABLES
Function / [ Setting ]
[0 ~ 255 / 0 / 1%/step]
3
/step]
* AH = absolute humidity
3.5
8.0
14
19
G071