Rev. 04/2003
Mode No.
5
(Class 1, 2, and 3)
104*
Double Count
1
Double Count
305*
ES Level 2 set
1
ES Level 2 set
401*
UlimitAutoSet
44
ULimitAutoSet
801
Memory Clear
1
All
2
ENG_All
3
SCS (System Control
Service)
4
IMH (Image Memory
Handler)
5
MCS (Memory Control
Service)
8
PRT
11
NCS
803
InputCheck (See section 5.3.2.)
804
OutputCheck (See section 5.3.3.)
810
SC_Reset
1
SC_Reset
SM
CÓPIA NÃO CONTROLADA
The counters count double for A3/11" x 17".
[0 ~ 1 / 0 / 1/step]
• 0: Normal count
• 1: Double count
Activates energy saver level 2.
[0 ~ 1 / 0 / 1/step]
• 0: Enables
• 1: Disables
Activates the auto user code registration function (prints
are counted and logged for each user code and the
counts can be viewed with SmartNetMonitor).
[0 ~ 1 / 1 / 1/step]0: Inactivated
• 1: Activated
Clears the settings from the NVRAM and initializes the
settings.
• Enter key: Clears
• Escape key: Does not clear
Clears the engine settings.
• Enter key: Clears
• Escape key: Does not clear
Clears the system settings.
• Enter key: Clears
• Escape key: Does not clear
Clears IMH data. DFU
• Enter key: Clears
• Escape key: Does not clear
Clears MCS data. DFU
• Enter key: Clears
• Escape key: Does not clear
MCS is for network settings.
Clears the user tool settings.
• Enter key: Clears
• Escape key: Does not clear
Clears the network settings.
• Enter key: Clears
• Escape key: Does not clear
Resets a fusing-related SC.
[0 ~ 1 / 0 / 1/step]
Resets a type A service call condition.
NOTE: Turn the main switch off and on after using this
SP.
5-33
CÓPIA NÃO CONTROLADA