SP MODE TABLES
Mode No.
2
(Class 1, 2, and 3)
510*
Fu_Bias_SW
1
Fu_Bias_SW
801*
ChrgClnIntval
1
ChrgClnIntval
2
ChrgClnIntval - 2
802
ChargerCln
1
Charger Cln
803
Charge Cleaning Off Time
1
Charge Cleaning Off
time
Requires MCU v2.26
and BICU v1.40
firmware.
901*
EnvControl
1
EnvControl
903
PaperTrans_Low
1
LL1/Nrml
904
1CBiasAdj
1
[M]
2
[C]
3
[Y]
4
[K]
G071
CÓPIA NÃO CONTROLADA
Switches the fusing and discharge pin bias control on or
off.
[0 ~ 1 / 1 / 1/step] DFU
• 0: Control off
• 1: Control on
Sets the charge corona unit cleaning interval.
[0 ~ 5000 / 600 / 100 counts/step]
Refer to section 6 for details.
Sets the charge corona unit cleaning interval.
The charge corona cleaning is carried out after 600
(SP2-801-1) development counts, at job end or after 700
(=the sum of the settings in SP2-801-1 and –2)
development counts (stops in the middle of the job)
[0 ~ 5000 / 100 / 100 counts/step]
Executes a forced charge corona unit cleaning.
Set to 1 to start cleaning.
[0 ~ 1 / 0 / 1/step]
A 60-second interval already exists for performing an
idle discharge after corona wire cleaning, this SP mode
allows the interval to be adjusted. The idle discharge is
to maintain an even charge wire surface, ensuring
proper charging. [0 ~ 200 / 60 / 10 seconds/step]
Switches environment control on or off.
[0 ~ 1 / 1 / 1/step] DFU
• 0: Control off (The paper transfer and cleaning bias
environments are set to NN1. The image transfer
bias environment is set to MM.)
• 1: Control on
Adjusts the paper transfer current applied when the
machine is at low temperature.
[0.0 ∼ 70.0 / 1.0 / 0.1 µA/step]
The specified value is subtracted from the value
specified by SP2-310 (PaperTrans_LL1) under the
following conditions:
• The machine is in the LL1 environment.
• 400 images or less are created after the machine
starts
Adjusts the development bias applied during the mono-
color mode. DFU
[0 ∼ 100 / 50 / 1 V/step]
[0 ∼ 100 / 0 / 1 V/step]
[0 ∼ 100 / 0 / 1 V/step]
[0 ∼ 100 / 0 / 1 V/step]
5-24
CÓPIA NÃO CONTROLADA
Function / [ Setting ]
Rev. 01/2004