SP MODE TABLES
3
(Class 1, 2, and 3)
913
Doctor Roller Rotation Interval M & K
1
Interval M
2
Interval K
920*
Lubrication Cleaning Time
1
1C
2
2C/3C/4C
921
Lubricant Clutch OFF
1
1 C
2
2C/3C/4C
940
JobEnd_Int
1
JobEnd_Int
941
OPC_Ide_PwrOn
1
Idling_Time
2
PrintingReady
G071
CÓPIA NÃO CONTROLADA
Mode No.
Controls the interval for performing reverse rotation on
the M and K doctor rollers at job end, in order to ensure
toner clumps do not form.
[1 ~ 50 / 1 / 1 /step]
[1 ~ 50 / 1 / 1 /step]
Sets the OPC belt lubrication period. DFU
[0 ~ 100 / 50 / 1%/step]
• When 100 is specified, the OPC belt cleaning clutch is
NOTE: Requires main unit controller version 2.27, and
BICU firmware version 1.42 or later.
[0 ~ 100 / 100 / 1%/step]
[0 ~ 11 / 6 / 1s /step]
Allows the image transfer belt cleaning clutch off timing
to be adjusted. The setting determines the number of
seconds after image transfer belt cleaning roller
charging that the clutch is turned off. With previous
versions, the clutch is always running while the
development roller motor rotates.
NOTE: Requires main unit controller version 2.27, and
BICU firmware version 1.42 or later.
The OPC belt is lubricated after the end of every job.
This SP determines whether the lubrication is interrupted
when a job arrives at the printer.
[0 ~ 1 / 0 / 1/step]
The image transfer belt tends to curl after a long period
without rotation.
To correct this, image transfer belt idling is done if the
fusing temperature is not high enough to print just after
the main switch is turned on.
This SP determines how long the idling rotation is done.
[3 ~ 5 / 3 / 1 minute/step]
Select when the machine can accept a print job after the
idling starts.
• 0: Immediately
• 1: After idling has been done for 1 minute
• 2: After idling finishes.
[0 ~ 2 / 0 / 1/step]
CÓPIA NÃO CONTROLADA
Function / [ Setting ]
always on whenever the OPC is turning, so the OPC
gets lubricated. When 50 is specified, the clutch is
only on half the time that the motor is on.
0: Interrupted
1: Not interrupted