Rev. 04/2003
Mode No.
5
(Class 1, 2, and 3)
833*
JobLog ON/OFF
7
JobLog ON/OFF
839
IEEE1394
4
Device Name
7
Cycle Master
8
BCR mode
9
IRM 1394a Check
10
Unique ID
11
Logout
12
Login
13
Login MAX
840
IEEE 802.11b
4
Current SSID
6
Channel Max
7
Channel Min
11
WEP key number
SM
CÓPIA NÃO CONTROLADA
Saves the results of jobs in the job log.
[0 ~ 1 / 0 / 1 /step]
• If this mode is enabled, the result data is written on
the HDD. If no HDD is installed, this feature is
disabled even if this SP is set to "enabled".
• 0: Disabled
• 1: Enabled
Displays the host name.
Activates/deactivates the cycle master function.
[0 ~ 1 / 1 / 1 /step]
• 0: Deactivates
• 1: Activates
Specifies the setting of the broadcast channel register
(BCR).
[0 ~ 3 / 3 / 1 /step]
• 0: Does not operate until IRM writes data
• 1: Wait awhile; copies the BCR of IRM if IRM does not
write data
• 2: (Reserved)
• 3: Always validates the BCR
Executes/does not execute the 1394a check of IRM (1
bit).
[0 ~ 1 / 0 / 1 /step]
• 0: Does not execute
• 1: Executes
Shows/does not show node unique IDs.
[0 ~ 1 / 1 / 1 /step]
• 0: Does not show
• 1: Shows
Specifies how the initiators are handled.
[0 ~ 1 / 1 / 1 /step]
• 0: Rejects the initiator if it tries to log in once again
after having logged off
• 1: Rejects the initiator if it tries to log on once again
after having logged off; then forcefully makes the
initiator log in
Validates/invalidates exclusive logon processing.
[0 ~ 1 / 0 / 1 /step]
• 0: Invalidates exclusive logon processing
• 1: Validates exclusive logon processing
Specifies the maximum number of initiators that are able
to log on.
[0 ~ 63 / 8 / 1 /step]
Displays the current SSID.
Specifies the maximum number of channels.
[0 ~ 14 / 0 / 1 /step]
Specifies the minimum number of channels.
[0 ~ 14 / 0 / 1 /step]
Displays the WEP key number.
5-35
CÓPIA NÃO CONTROLADA
SP MODE TABLES
Function / [ Setting ]
G071