Commissioning
10.3.3.1 Parameterizing the Product via OPC UA
10.3.3.1.1 Identifying Devices
The device provides nodes for device identification. For example, the OPC UA client can
read out the version of the device firmware used in the SoftwareRevision node. The
path to this node is:
Root > Object > DeviceSet > [device name]
Node Name
Manufacturer
ManufacturerUri
Model
ProductCode
RevisionCounter
SerialNumber
SoftwareRevision
76
Product manual | Version: 2.2.0
16DO FLD PN DC 24V 2.0A
Node Class
Access
Variable
Read
Variable
Read
Variable
Read
Variable
Read
Variable
Read
Variable
Read
Variable
Read
765-1103/100-000
Figure 27: OPC UA: Device Information Model
Table 40: Identify Devices
Description
Device manufacturer
URL of the device manufacturer
Short name of the device
Product code of the device: "765-xxxx/xxxx-
xxxx"
Hardware version of the device
Serial number of the device
Revision/version of the device firmware