Disable A Key Access User; Delete Keypad User(S) Using The Keypad - Kaba PowerLever 455 Series Operating Instructions Manual

Table of Contents

Advertisement

Step
6.
Repeat Steps 4–5 to enable
more Key Access Users or
go to step 7.
7.
Press
.

Disable a Key Access User

Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 72.
4.
Enter Key User ID.
5.
Enter Key User ID again.
6.
Repeat Steps 4–5 to disable
more Key Access Users or
go to step 7.
7.
Press
.

Delete Keypad User(s) Using the Keypad

Note: This operation is used to delete Keypad Access Users, Audit Users, and Service Users from the lock.
Note: If at any time during the procedure the lock power drops below a sufficient level for operation, the lock will con-
tinually beep and flash the red LED, prompting the user to depress the outside lever to provide additional power.
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
26
Detailed Instructions
If additional Key Access Users are to be enabled, repeat steps 4-5 until all
User IDs have been enabled. If no additional Key Access Users are to be
enabled, go to step 7.
Press
(Enter key) to exit this procedure. The lock responds with two
simultaneous beeps/flashes of the green and red LEDs and exits this
procedure.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
Before re-lock time expires, press
then the 2 key. The lock responds with two beeps/flashes of the green LED.
Enter the four-digit User ID of the Key Access User to be disabled. The lock
responds with two beeps/flashes of the green LED if the User ID is valid.
The lock responds with two beeps/flashes of the red LED to indicate an
error.
Enter the four-digit Key User ID again for verification. The lock responds with
four beeps/flashes of the green LED. The lock responds with two
beeps/flashes of the red LED if the User ID was unconfirmed or if the User
ID was not in use.
The Key Access User is now disabled.
If additional Key Access Users are to be disabled, repeat steps 4-5 until all
User IDs have been disabled. If no additional Key Access Users are to be
disabled, go to step 7.
Press
(Enter key) to exit this procedure. The lock responds with two
simultaneous beeps/flashes of the green and red LEDs and exits this
procedure.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
(Enter key) followed by the 7 key and