Disable a Keypad User

Note: This operation is used to disable lock access for either Keypad Access Users or Service Users.
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 70.
4.
Enter Keypad User ID.
5.
Enter Keypad User ID again.
6.
Repeat Steps 4–5 to disable
more Keypad Users or go to
step 7.
7.
Press
.

Enable a Key Access User

Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 73.
4.
Enter Key User ID.
5.
Enter Key User ID again.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
Before re-lock time expires, press
then the 0 key. The lock responds with two beeps/flashes of the green LED.
Enter the User ID of the Keypad User to be disabled. The lock responds
with two beeps/flashes of the green LED if the User ID is valid. The lock
responds with two beeps/flashes of the red LED to indicate an error.
Enter the Keypad User ID again for verification. The lock responds with four
beeps/flashes of the green LED. The lock responds with two beeps/flashes
of the red LED if the User ID was unconfirmed, if the User ID was not in use,
or if the User ID was not that of a Keypad Access User or a Service User.
The Keypad User is now disabled.
If additional Keypad Users are to be disabled, repeat steps 4–5 until all User
until all User IDs are disabled. If no additional Keypad Users are to be dis-
abled, go to step 7.
Press
(Enter key) to exit this procedure. The lock responds with two
simultaneous beeps/flashes of the green and red LEDs and exits this
procedure.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
Before re-lock time expires, press
then the 3 key. The lock responds with two beeps/flashes of the green LED.
Enter the four-digit User ID of the Key Access User to be enabled. The lock
responds with two beeps/flashes of the green LED if the User ID is valid.
The lock responds with two beeps/flashes of the red LED to indicate an
error.
Enter the four-digit Key User ID again for verification. The lock responds with
four beeps/flashes of the green LED. The lock responds with two
beeps/flashes of the red LED if the User ID was unconfirmed or if the User
ID was not in use.
The Key Access User is now enabled.
(Enter key) followed by the 7 key and
(Enter key) followed by the 7 key and
25