Step
3.
Press
then 50.
4.
Enter User's new
combination.
5.
Enter User's new combination
again (User ID + new PIN).

Change Key Access User PIN

Note: This operation is only applicable if PIN length is not 0.
Step
1.
Power lock.
2.
Insert Access User Key into
key reader.
3.
Enter Key Access User PIN.
4.
Press
then 51.
5.
Enter new PIN.
6.
Enter the new PIN again.

Change Master User Combination (User ID + PIN)

Note: The new User ID that is selected must be an available ID (one that has not already been selected for another
user).
Step
1.
Power lock.
2.
Enter Master User
combination.
Detailed Instructions
Before re-lock time expires, press
then the 0 key. The lock responds with two beeps/flashes of the green LED.
Enter the new Manager User or Keypad Access User combination (User ID
+ new PIN). The lock responds with two beeps/flashes of the green LED if
the combination was verified successfully. The lock responds with two
beeps/flashes of the red LED to indicate an error.
Enter the Manager User or Keypad Access User combination again for
verification. The lock responds with two simultaneous beeps/flashes of the
green and red LEDs if the combination was verified successfully. The lock re-
sponds with two beeps/flashes of the red LED to indicate an error.
The new PIN is now active for the user.
Detailed Instructions
Power the lock by depressing the outside lever.
Insert the Access User Key into the lock key reader. The lock responds with
two beeps/flashes of the green LED.
Enter the four-digit PIN for the Key Access User. The lock responds with
three beeps/flashes of the green LED to indicate available entry. If the lock
PIN is not valid, the lock responds with two beeps/flashes of the red LED.
(Note: For a User who has not changed the default PIN, the lock will not open.)
Before re-lock time expires, press
then the 1 key. The lock responds with two beeps/flashes of the green LED.
The lock responds with two beeps/flashes of the red LED if the opener was
a Keypad Access User or a Key Access User that does not require a PIN for
lock access.
Enter the Key Access User's new PIN. The lock responds with two beeps/
flashes of the green LED. The lock responds with two beeps/flashes of the
red LED to indicate an error.
Enter the Key Access User's new PIN again for verification. The lock
responds with two simultaneous beeps/flashes of the green and red LEDs.
The lock responds with two beeps/flashes of the red LED to indicate an error.
The new PIN is now active for the Key Access User.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the current Master User combination. The lock will beep/flash the
green LED on each keystroke entered. If the Clear key is pressed during
data entry, the lock responds with one beep/flash of the green LED followed
by the red LED, and all digits of the combination must be re-entered. The
lock responds with three beeps/flashes of the green LED to indicate avail-
able entry. If the combination is not valid, the lock responds with three
beeps/flashes of the red LED.
(Enter key) followed by the 5 key and
(Enter key) followed by the 5 key and
19